2-7
Installation and Upgrade Guide for Cisco Unified MeetingPlace Audio Server 6.x
OL-13417-01
Chapter 2 Installing the Cisco Unified MeetingPlace 8100 Series Hardware
Mounting the Cisco Unified MeetingPlace 8100 Series
Figure 2-4
Mounting the Cisco Unified MeetingPlace 8112 into an EIA Equipment Rack
Mounting the Breakout Box for T1 PRI and E1 Cisco Unified MeetingPlace
Systems
Note
If the Cisco Unified MeetingPlace system does not require a breakout box (T1 PRI or E1 configuration),
skip to the
“Connecting the Power Cable to the Cisco Unified MeetingPlace 8100 Series” section on
page 2-11
.
The breakout box provides a standard RJ-45 telephony interface. The breakout box interfaces to a
maximum of 16 cables with an MP-MA-16-PRI and a maximum of 4 cables with each MP-MA-4-PRI.
Cisco Systems ships the necessary number of RJ-48c cables to connect each breakout box to your PBX
or Telco NIU with each Multi Access Blade.
Note
In some cases, the RJ-48c cables provided by Cisco Systems may not be appropriate for your PBX or
NIU side connections. If this is the case, create your own custom cables, which require an RJ-48c
connector on the breakout box side. (For custom-cable requirements, see the
“E1 Digital Trunk
Requirements for Cisco Unified MeetingPlace Systems” section on page 1-10
.)
Cisco Systems also ships the necessary number of 50-pin Amphenol cables with the breakout box: two
50-pin Amphenol cables to connect each MP-MA-16-PRI to the breakout box and one 50-pin Amphenol
cable to connect each MP-MA-4-PRI to the breakout box.
If the Cisco Unified MeetingPlace system requires two MP-MA-16-PRIs, you need two breakout boxes.
(A fully loaded 960-port E1 Cisco Unified MeetingPlace system and a fully loaded 736-port T1 PRI
Cisco Unified MeetingPlace system have two MP-MA-16-PRIs.)
Note
Only the Cisco Unified MeetingPlace 8112 can have two breakout boxes.
1
2
3
4
5
6
7
8
1
2
9
1
2
3
4
10
11
12
13
14
15
16
1
2
1
2
3
4
1
2
1
2
3
4
1
2
1
2
3
4
1
2
1
2
3
4
1
PWR ON
PWR OFF
2
OUT OF
SERVICE
OUT OF
SERVICE
1
OUT OF
SERVICE
OUT OF
SERVICE
2
OUT OF
SERVICE
OUT OF
SERVICE
3
OUT OF
SERVICE
OUT OF
SERVICE
4
OUT OF
SERVICE
OUT OF
SERVICE
5
OUT OF
SERVICE
OUT OF
SERVICE
6
OUT OF
SERVICE
OUT OF
SERVICE
OUT OF
SERVICE
OUT OF
SERVICE
OUT OF
SERVICE
OUT OF
SERVICE
OUT OF
SERVICE
OUT OF
SERVICE
OUT OF
SERVICE
OUT OF
SERVICE
11
OUT OF
SERVICE
OUT OF
SERVICE
12
OUT OF
SERVICE
OUT OF
SERVICE
13
OUT OF
SERVICE
OUT OF
SERVICE
14
OUT OF
SERVICE
OUT OF
SERVICE
15
OUT OF
SERVICE
OUT OF
SERVICE
16
7
8
9
10
Rack-mounting
holes
92344