2-25
Installation and Upgrade Guide for Cisco Unified MeetingPlace Audio Server 6.x
OL-13417-01
Chapter 2 Installing the Cisco Unified MeetingPlace 8100 Series Hardware
About Telephony Configurations for E1 and T1 PRI Cisco Unified MeetingPlace Systems
Step 4
Repeat
Step 2
and
Step 3
until all the E1 or T1 PRI telephony cables are connected to the breakout box.
Place the second, third, and fourth E1 or T1 PRI telephony cables, which correspond to the first
MP-MA-4-PRI, into the RJ-45 jacks labeled 2, 3, and 4. Place the second set of four E1 or T1 PRI
telephony cables, which corresponds to the second MP-MA-4-PRI, into the RJ-45 jacks labeled 9, 10,
11, and 12.
Note
The RJ-45 jacks labeled 5 to 8 and 13 to 16 remain empty.
Step 5
Connect the trunk card cable assembly (50-pin Amphenol cable) for the first Multi Access Blade to the
back of the breakout box by securing the screws on both ends.
Looking at the back of the breakout box, place the first trunk card cable assembly into the connector on
the right.
Step 6
Connect the other end of the trunk card cable assembly (50-pin Amphenol cable) for the first
Multi Access Blade into the Multi Access Blade transition module by securing the screws on both ends.
For the Cisco Unified MeetingPlace 8106, place the 50-pin Amphenol cable into the connector on the
left, labeled spans 9 to 16.
For the Cisco Unified MeetingPlace 8112, place the 50-pin Amphenol cable into the connector on the
bottom, labeled spans 9 to 16.
Step 7
Repeat
Step 5
and
Step 6
for the trunk card cable assembly (50-pin Amphenol cable) for the second
Multi Access Blade.
For the Cisco Unified MeetingPlace 8106, place the 50-pin Amphenol cable into the connector on the
left side of the breakout box and on the left of the Multi Access Blade in the connector labeled spans
9 to 16.
For the Cisco Unified MeetingPlace 8112, place the 50-pin Amphenol cable into the connector on the
left side of the breakout box and on the bottom of the Multi Access Blade in the connector labeled spans
9 to 16.
Connecting E1 or T1 PRI Telephony Cables with One Multi Access Blade
MP-MA-16-PRI and One Multi Access Blade MP-MA-4-PRI
This configuration is supported only on a Cisco Unified MeetingPlace 8112.
To Connect E1 or T1 PRI Telephony Cables with One Multi Access Blade MP-MA-16-PRI and One Multi Access
Blade MP-MA-4-PRI
Step 1
Locate the following items that shipped with the Cisco Unified MeetingPlace 8112:
•
E1 or T1 PRI telephony cables.
•
Two breakout boxes, which should already be mounted above the Cisco Unified MeetingPlace 8112.
•
Trunk card interface cable assemblies (50-pin Amphenol cables).