1-41
Cisco 7100 Series VPN Router Installation and Configuration Guide
78-6341-03
Chapter 1 Overview
Functional Overview
The show environment command displays the current environmental status of the system. The report
displays parameters that are out of the normal values. No parameters are displayed if the system status
is normal. The example that follows shows the display for a system in which all monitored parameters
are within normal range:
Router#
show environment
All measured values are normal
If the environmental status is not normal, the system reports the worst-case status level. Following is a
sample overvoltage warning:
Router#
show environment
Warning: +3.3 V measured at +3.41 V
The show environment last command retrieves and displays the NVRAM log, which provides a record
of environmental status readings. Air temperature is measured and displayed, and the voltage supplied
by the power supply is also displayed.
Following is sample output of the show environment last command:
Router#
show environment last
chassis corepreviously measured at 34C/93F
chassis inletpreviously measured at 28C/82F
chassis outlet 1previously measured at 31C/87F
chassis outlet 2previously measured at 33C/91F
+2.5 Vpreviously measured at +2.59
+3.3 Vpreviously measured at +3.32
+5.15 Vpreviously measured at +5.13
+12.3 Vpreviously measured at +12.99
+12.3 Vpreviously measured at +12.33
-12.5 Vpreviously measured at -12.43
The show environment table command displays the temperature and voltage thresholds for each
temperature sensor and for each monitored status level, which are related to those thresholds listed in
Table 1-17
and
Table 1-18
.
Following is sample output of the show environment table command:
Note
Temperature ranges and values are subject to change.
The show environment all command displays an extended report that includes temperature readings and
voltage readings.
Following is sample output of the show environment all command:
Router#
show environment all
Router#
show environment table
Sample Point
LowCritical
LowWarning
HighWarning
HighCritical
chassis core
chassis inlet
chassis outlet 1
chassis outlet 2
49C/120F
43C/109F
46C/114F
47C/116F
54C/129F
48C/118F
51C/123F
52C/125F
+2.5 V
+3.3 V
+5.15 V
+12.3 V
+12.3 V
-12.5 V
+2.35
+3.11
+4.88
+11.53
+11.53
-10.20
+2.39
+3.19
+5.00
+11.77
+11.77
-11.24
+2.69
+3.39
+5.23
+12.76
+12.76
-13.71
+2.72
+3.47
+5.39
+13.05
+13.05
-14.33