1-24
Cisco 7500 Series Installation and Configuration Guide
OL-5008-03 B0
Chapter 1 Cisco 7500 Series Product Overview
Cisco 7513-MX Overview
Cisco 7513-MX System Specifications
Table 1-5
lists the specifications for the Cisco 7513-MX system.
Table 1-5
Cisco 7513-MX Specifications
Description
Specification
Backplane
Two 1.0677-Gbps CyBuses: 11 interface processor slots, 2 RSP slots
Dimensions
(H x W x D)
33.75 x 17.5 x 22 in. (85.73 x 44.45 x 55.88 cm)
Chassis width including rack-mount flanges is 18.93 in. (48.1 cm)
Chassis depth including power cables and cable-management bracket is 24 in. (60.96 cm)
Weight
Chassis with blower module: 75 lb (34.02 kg)
Chassis with blower module and 1 power supply: 100 lb (45.36 kg)
Chassis with blower module and 2 power supplies: 125 lb (56.7 kg)
Chassis with blower module, 2 power supplies, and all slots filled: ~160 lb (72.58 kg),
each processor module weighs ~2.5 lb (1.13 kg)
Power dissipation
1600W with a maximum configuration and 1 AC-input power supply
1600W with a maximum configuration and 1 DC-input power supply
1700W nominal with a maximum configuration and either 2 AC-input or 2 DC-input power
supplies
Heat dissipation
1600W (5461 Btu/hr)
AC-input voltage
100 to 240 VAC
Frequency
50/60 Hz
AC-input cable
1
1.
The Cisco 7513-MX requires a minimum of 20A service with a 20A receptacle at the power source. The power cable supplied with the Cisco 7513-MX
uses a 20A male plug.
12 AWG, with 3 leads, an IEC-320 plug on the router end, and a country-dependent plug on the
power source end
AC-input voltage
and current
100 VAC at 16 amps (A) maximum, wide input with power factor corrector (PFC)
240 VAC at 7A maximum
DC-input voltage
and current
–48 VDC nominal at 35A in North America (–60 VDC at 35A in the European Union)
DC-input cable
8 AWG (recommended minimum), with 3 leads and rated for at least 194°F (90°C) (you supply the
cable)
Power distribution
+5.2 VDC @ 75A, +12 VDC @ 15A, –12 VDC @ 3A, +24 VDC @ 5A
Airflow/noise level
Bottom to top through chassis by variable-speed blower (62 to 70 dBA)
Temperature
32 to 104°F (0 to 40°C), operating; –4 to 149°F (–20 to 65°C), nonoperating
Relative humidity
10 to 90%, noncondensing
Software requirement
RSP2 – Cisco IOS Release 10.3(6) or a later release of 10.3
RSP4/4+ – Cisco IOS Release 11.1(8)CA or a later release of 11.1
RSP8 – Cisco IOS Release 12.0(9)S or a later release of 12.0 S
RSP16 – Cisco IOS Release
12.1(12)E and later and Cisco IOS 12.0(21.02)S and later
Agency approvals
Safety: UL 1950, CSA 22.2-950, EN60950, EN41003, TS001, AS/NZS 3260
EMI: FCC Class A, EN60555-2, EN55022 Class B, VDE 0878 Part 3, 30 Class B
Immunity: EN55101/2 (ESD), EN55101/3 (RFI), EN55101/4 (Burst), EN55101/5 (Surge),
EN55101/6 (Conducted), IEC77B (AC Disturbance)