4038501 Rev C
Operation
3-17
Setting Up the AGC Module
When the AGC module is plugged into the amplifier, it reads the settings, including
pilot settings and function settings from the amplifier, and starts to run the
configured function.
CAUTION:
When a SMC transponder will be installed, make sure its mode is set to IEP,
before configuring the AGC module. Refer to page 3-15 for details.
Setting Up the AGC Module with a Handheld Terminal
The following steps provide instructions on setting up the AGC module with a
handheld terminal. Before using the AGC module to monitor and control the output
signals of the amplifier, check the pilot settings to make sure they have been set to
the desired values.
1.
Connect Terminal A91200 to the amplifier by plugging the connector of the
terminal into the LCI socket. The display on the terminal shows the status of the
AGC module.
2.
Press
to navigate to menu ”7 AGC Module” and press
to open the
submenu. Go to “71 Pilot Settings” in the submenu by pressing
again.
3.
Press
to enter the submenu “711 Pilot Hi Freq”, and press
to
change the value of pilot high frequency. The menu title “711 Pilot Hi Freq” will
be flashing when the value can be changed. Use the number keys to enter the
desired value and press
E
N
T
E
R
to confirm.
4.
Go to “712 Pilot Hi Level” and repeat step 3 to set up pilot high level.
5.
Press
to return to submenu “71 Pilot Settings” and repeat steps 3 and 4, to
set up pilot low frequency and level.
Note
: Frequency and level have configurable ranges. See page 3-7 for details. Value
input out of the specified range will not be effective, and an “Out of Range” display
will appear.
6.
Before using the auto alignment function, the cable temperature also has to be set
up. Go to submenu “73 Temp Backoff” and press
and
to select the
desired value. Press
E
N
T
E
R
to confirm. When the auto alignment is completed, the
temperature returns to 20
℃
by default.