C I S C O C O N F I D E N T I A L - D r a f t A 1
2-11
Cisco Aironet 1250 Series Access Point Hardware Installation Guide
OL-8247-02
Chapter 2 Installing the Access Point
Mounting Above a Suspended Ceiling
Mounting Above a Suspended Ceiling
The access point mounting plate is designed to be integrated into the T-bar grid above the tiles of a
suspended ceiling. Using a T-bar box hanger and bracket mounting clip (not supplied) such as the
Erico 512A with BHC mounting clip, you orient the access point antenna just above the top surface of a
standard ceiling tile. You may need to modify a thicker tile to allow room for the antenna.
before proceeding.
Figure 2-4
Above Suspended Ceiling Parts
Caution
The 1250 series power injector (AIR-PWRINJ4), 1250 series DC power module (AIR-PWR-SPLY1),
and the antennas have not been tested to UL 2043 and they should not be placed in a building’s
environmental air space, such as above suspended ceilings.
1
Suspended ceiling T-rail
4
T-bar box hanger
2
T-rail clip
5
Bracket mounting clip
3