19-5
Cisco Aironet 1400 Series Wireless Bridges Software Configuration Guide
OL-4059-01
Chapter 19 Troubleshooting
Power Injector LEDs
The power injector LEDs are shown in
Figure 19-2
.
Figure 19-2 Power Injector LEDs
The power injector LED indications are shown in
Table 19-3
.
1
Power jack (+48 VDC)
5
Ethernet port (RJ–45 connector)
2
Power LED
6
Ethernet Activity LED
3
Power injector dual-coax ports (F-Type connectors)
7
Injector Status LED
4
Mode button
8
Uplink Activity LED
88820
1
2
4
5
8
7
6
3
Ipsam
y opsum
Ipsam
y opsum
Ipsam
y opsum
Table 19-3 Power Injector LED Indications
Uplink Activity
Injector Status
Ethernet Activity Description
—
—
Off
Wired LAN Ethernet link is not active.
—
—
Green
Wired LAN Ethernet link is operational.
—
—
Blinking Green
Transmitting and receiving packets over the
wired LAN Ethernet link.
—
—
Amber
Power injector internal memory
error—disconnect and reconnect the power
injector power plug. If the problem continues,
contact technical support for assistance.
Off
—
—
Link between power injector and bridge is not
active. This might be caused by improper
connections or a defective cable or connector.
Verify that the dual-coax cables are connected
correctly to the power injector, grounding
block, and bridge. If the cables are connected
correctly, contact technical support for
assistance.
Green
—
—
Link between power injector and bridge is
operational.