Error and Event Messages
This appendix lists the CLI error and event messages.
Table D-1
lists the errors and events and provides
an explanation and recommended action for each message.
Table D-1
Error and Event Messages
Message
Explanation
Recommended Action
Software Auto Upgrade Messages
SW_AUTO_UPGRADE-FATAL:
Attempt to upgrade software failed,
software on Flash may be deleted.
Please copy software into Flash.
Auto upgrade of the software failed. The
software on the Flash memory might have
been deleted. Copy software into the
Flash memory.
Copy software before rebooting the
unit.
SW_AUTO_UPGRADE-7-FAILURE:
dhcp_client_start_stop failed
Auto upgrade of the software failed due
to error in starting/stopping DHCP client
process.
Copy the error message exactly as it
appears and report it to your technical
support representative.
SW_AUTO_UPGRADE-7-FAILURE:
Failed to obtain ip addr from dhcp server
Auto upgrade of the software failed.
Copy the error message exactly as it
appears and report it to your technical
support representative.
SW_AUTO_UPGRADE-7-FAILURE:
boot_file_pathent creation failed
Auto upgrade of the software failed due
to error in creation of pathent (internal
data structure).
Copy the error message exactly as it
appears and report it to your technical
support representative.
Association Management Messages
DOT11-2-RADIO_HW_RESET: Radio
subsystem is under going hardware reset
to recover from problem
Radio must be reset due to problem.
None.
DOT11-3-BADSTATE: [mac-address]
[chars] [chars] -> [chars]
802.11 Association and management uses
a table-driven state machine to keep track
and transition an Association through
various states. A state transition occurs
when an Association receives one of
many possible events. When this error
occurs, it means that an Association
received an event that it did not expect
while in this state.
The system can continue but may lose
the Association that generates this
error. Copy the message exactly as it
appears and report it to your technical
service representative.
DOT11-3-RADIO_OVER_
TEMPERATURE: Interface [interface]
Radio over temperature
The bridge detected that the unit has
exceeded the radio operating
temperature.
Investigate and take steps to cool the