C i s c o C o n f i d e n t i a l - D r a f t 1
2-18
Cisco Aironet 1500 Series Outdoor Mesh Access Point Hardware Installation Guide
OL-9977-05
Chapter 2 Mounting Instructions
Mounting the Access Point
Step 1
From the pole mount kit, use four of the supplied short bolts, lock washers, and flat washers to attach
the pole mount kit adjustment plate to the access point mounting plate as shown in
Figure 2-8
. Tighten
the bolts to 15 to 20 ft. lbs. (20 to 27 Nm).
Figure 2-8
Adjustment Plate Attached to the Mounting Plate
142686
Step 2
Select a mounting location. You can attach the access point to any pole from 1.66 to 3.35 in. (4.22 to
9.02 cm) in diameter.
Note
If you will be using a streetlight power tap adapter, position the access point within 3 ft (1 m) of
the outdoor light control.
Step 3
Loosely assemble the pole clamp components around the pole and thread the four long bolts into the
clamp adjustment plate.
Figure 2-9
shows the pole clamp attached to a pole with the clamp adjustment
plate positioned on the bolts.