Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
IVR Messages
Error Message
IVR-3-DEVICE_NOT_PREENT_IN_FB_DB_FICON: Device with port WWN [chars]
could not be exported to VSANs [chars] because its native switch is not present
in the current active fabric binding database of those VSANs.
Explanation
This happens if FICON is enabled on VSANs [chars] and native switch of device with
port WWN [chars] is not present in the current active fabric binding database of those VSANs. This
is a requirement for FICON compliance.
Recommended Action
No action is required.
Error Message
IVR-3-DEVICE_ON_WRONG_NATIVE_AFID_VSAN: Device with port WWN [chars]
(FCID:[chars], native VSAN [dec] native AFID [dec]) may not be exported to other
VSANs (for Inter-VSAN zoning) because it has come online in VSAN [dec] AFID [dec]
Explanation
Device has come online on a AFID/VSAN different from the configured native
AFID/VSAN.
Recommended Action
No action is required.
Error Message
IVR-3-DEVICE_ON_WRONG_NATIVE_VSAN: Device with port WWN [chars]
(FCID:[chars], native VSAN [dec]) may not be exported to other VSANs (for
Inter-VSAN zoning) because domain [hex] exists in VSAN [dec]
Explanation
Device has come online on a VSAN different from the configured native VSAN or the
device does not satisfy unique domain criteria.
Recommended Action
No action is required.
Error Message
IVR-3-DM_ERROR: Domain Manager API, [chars], failed with error [hex]
Explanation
IVR invoked DM API and received the error code. [chars] describes the API and
0x[hex] specifies the error.
Recommended Action
No action is required.
Error Message
IVR-3-DOMAIN_DISALLOWED_IN_INTEROP: Device with port WWN [chars] and
FCID [chars] may not be able to participate in Inter-VSAN zone since domain [dec]
is disallowed in the interop mode for VSAN [dec]
Explanation
VSAN interop modes place restrictions on what domain ranges are allowed. This
domain is out of the range allowed for this interop mode. See the Cisco MDS 9000 Family
Configuration Guide for details on the domain range limitations.
Recommended Action
Change the domain of the switch to which this IVR zone member is connected
to so that it is within the allowed domain list for the interop mode. The domain identifier can be
statically assigned using fcdomain interface. You can also configure a range of domains allowed in
a VSAN using the fcdomain's 'allowed-domains' interface.