S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
2-746
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
TUNNEL Messages
TUNNEL-4
Error Message
TUNNEL-4-TM_DF_PROGRAMMING: Programming [chars] DF(dont fragment)
df.sel [dec] df.val [dec]
Explanation
Programming [chars] DF df.sel [int] df.val [int].
Recommended Action
No action is required.
Error Message
TUNNEL-4-TM_DF_PROGRAMMING_FAILED: [chars] DF(dont fragment)
programming failed! status [hex]
Explanation
[chars] DF programming failed! status [int].
Recommended Action
Capture show tech-support tunnel to identify why df flag programing failed.
Error Message
TUNNEL-4-TM_DUPLICATE_TUNNEL: configuration
Explanation
Duplicate tunnel configuration is not allowed.
Recommended Action
No action is required.
Error Message
TUNNEL-4-TM_MTU_PROGRAMMING: Programming [chars] mtu [dec]...
Explanation
Programming [chars] mtu [int].
Recommended Action
No action is required.
Error Message
TUNNEL-4-TM_MTU_PROGRAMMING_FAILED: [chars] mtu [dec] programming
failed! status [hex]
Explanation
[chars] mtu [int] programming failed! status [int].
Recommended Action
Capture show tech-support tunnel to identify why MTU programming as
failed. tunnel interface will used default mtu value.
TUNNEL-5
Error Message
TUNNEL-5-IF_CLEAR_COUNTER: Interface [chars] counters is cleared
Explanation
Interface [char] counters is cleared.
Recommended Action
No action is required.