4-5
Cisco AS5350 Universal Gateway Chassis Installation Guide
78-10754-03 0A
Chapter 4
Troubleshooting
Monitoring Environment
The display below appears on your console when the system reaches a critical state:
Router# show environment
Temperature:
Temperature Reading:
Temperature at inlet is measured as 62C/143F.
Temperature at outlet is measured as 74C/165F.
Temperature State:
Temperature is in critical state.
DFC Busyout/Power-down:
A DFC is powered down. Slot:1, Type:NP60 DFC
A DFC is busyout. Slot:2, Type:T1 2 PRI DFC
A DFC is busyout. Slot:3, Type:NP60 DFC
Fans:
Fans temperature delta is measured as 6C.
All fans are running well.
Power Supply:
Power System is present.
PS Input Voltage status: normal
PS Output Voltage status: normal
PS Fan status: normal
PS Thermal status: normal
PS OverVoltage status: normal
Environmental monitor experienced the following events:
Temperature:sensor failed.
Fans:monitor dropped.
Temperature:warning.
Temperature:sensor recovered.
Fans:monitor recovered.
Fans:normal.
Temperature:critical.
The display below appears on your console when the system reaches a shutdown state:
Router# show environment
Temperature:
Temperature Reading:
Temperature at inlet is measured as 70C/158F.
Temperature at outlet is measured as 82C/179F.
Temperature State:
Temperature is in shutdown state.
DFC Busyout/Power-down:
A DFC is powered down. Slot:1, Type:NP60 DFC
A DFC is powered down. Slot:2, Type:T1 2 PRI DFC
A DFC is powered down. Slot:3, Type:NP60 DFC
Fans:
Fans temperature delta is measured as 6C.
All fans are running well.
Power Supply:
Power System is present.
PS Input Voltage status: normal
PS Output Voltage status: normal
PS Fan status: normal
PS Thermal status: normal
PS OverVoltage status: normal