4-9
Cisco AS5350 and Cisco AS5400 Universal Gateway Software Configuration Guide
OL-3418-02 B0
Chapter 4
Continuing Configuration Using the Command-Line Interface
Configuring E1 R2 Signaling
Country Codes for R2 Signaling
Table 4-1
lists the country codes supported for R2 signaling.
.
Verify
To verify your R2 signaling configuration:
•
Enter the show controller e1 command to view the status for all controllers, or enter the
show controller e1 # to view the status for a particular controller. Make sure the status indicates the
controller is up (line 2 in the following example) and no alarms (line 4 in the following example) or
errors (lines 9 and 10 in the following example) have been reported.
AS5350# show controller e1 0/0
E1 0/0 is up.
Applique type is Channelized E1 - balanced
No alarms detected.
Version info of Slot 0: HW: 2, Firmware: 4, PLD Rev: 2
Manufacture Cookie is not programmed.
Framing is CRC4, Line Code is HDB3, Clock Source is Line Primary.
Data in current interval (785 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
Total Data (last 13 15 minute intervals):
0 Line Code Violations, 0 Path Code Violations,
0 Slip Secs, 12 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 12 Unavail Secs
Table 4-1
Country Codes for R2 Signaling
argentina
greece
paraguay
australia
guatamala
peru
bolivia
hongkong-china
philippines
brazil
india
saudiarabia
bulgaria
indonesia
singapore
china
israel
southafrica-panaftel
colombia
itu
telmex
costarica
korea
telnor
croatia
laos
thailand
easteurope
malaysia
uraguay
equador-itu
malta
venezuela
ecuador-lme
newzealand
vietnam