Cisco AS5400XM Universal Gateway Chassis Installation Guide
OL-6418-02
Chapter 3 Installing the Cisco AS5400XM Universal Gateway
Connecting to the Alarm Port
Figure 3-12
Connecting to the BITS Port
Connecting to the Alarm Port
Connect to the alarm port as follows:
Step 1
Insert the three-pin alarm port connector into the alarm port terminal block. (See
Figure 3-13
.)
Figure 3-13
Connecting to the Alarm Port
Note
Connect the alarm port only to a safety extra-low voltage (SELV) source using 22 AWG, or
thicker, copper wire. SELV ratings are maximum 30 volts AC (RMS), maximum 60 volts DC,
and maximum 50 VA power. The alarm port is rated for 2.0-amp maximum current.