4-13
Cisco ASA 5585-X Adaptive Security Appliance Hardware Installation Guide
OL-22567-02
Chapter 4 Maintenance and Upgrade Procedures
Removing and Installing the Power Supply Module
Figure 4-11
shows the AC power-supply module indicator lights.
Figure 4-11
AC Power Supply Module Indicator Lights
Table 4-3
describes the AC power supply module indicators.
Removing and Installing an AC Power Supply Module
Caution
If you remove a power supply or fan module, replace it immediately to prevent disruption of service.
Caution
If the appliance is subjected to environmental overheating, it shuts down and you must manually power
cycle it to turn it on again.
Cisco ASA 1200W AC
100-240V
15.0/8.0.A
56/60Hz
IN
OK
FA
N
OK
OUT
FAIL
253905
1
2
3
Table 4-3
AC Power Supply Module Indicators
Figure
Label
Indicator
Description
1
IN OK
Status of the power supply module:
•
Off—No AC power cord connected, or AC power switch is off.
•
Green—AC power cord connected and AC power switch is on.
2
FAN OK
Status of the fan module
•
Off—Fan module failure, or AC power switch is off.
•
Green—AC power cord connected, AC power switch is on, and internal fan
is running.
3
OUT FAIL
•
Red—Output voltage failure
1
1.