b) Secure the lug to the -VDC terminals with the remaining two washers and nuts that you removed in step 3. The nuts
should be torqued to 50 in-lb. (5.65 N-m).
To avoid the risk of fire, take proper precautions to ensure that the power feed and return lugs are not touching. Um
einen Kurzschluss zu vermeiden, duerfen sich die beiden Stromkabel nicht beruehren. Kabelschuhe duerfen sich
nicht beruehren und muessen unbedingt auseinander gehalten werden.
Step 6
Reinstall the plastic terminal cover.
To avoid the risk of potential damage to the system, never operate the chassis without the plastic terminal
cover installed. Make sure that the power and return lugs do not protrude past the edge of the plastic terminal
covers. Any portion of the lug that is exposed must be covered with heat shrink tubing.
Caution
Step 7
Repeat step 1 through step 6 for the PFU installed in the bay labeled Power Filter Unit 2.
Step 8
Proceed to the next chapter for information and instructions on applying power to the chassis and verifying that the
installation was successful.
ASR 5000 Installation Guide
131
Cabling the Power Filter Units
Connecting the PFU to the Power Source
Summary of Contents for ASR 5000
Page 16: ...ASR 5000 Installation Guide xvi About this Guide Contacting Customer Support ...
Page 64: ...ASR 5000 Installation Guide 48 Installation Procedure Overview Laser Notice ...
Page 100: ...ASR 5000 Installation Guide 84 Line Card Installation Installing the XGLC ...
Page 122: ...ASR 5000 Installation Guide 106 Cabling the Fast Ethernet 10 100 Line Card FLC2 Interfaces ...
Page 206: ...ASR 5000 Installation Guide 190 Removing and Installing SMC PC Cards Removing PC Cards ...
Page 212: ...ASR 5000 Installation Guide 196 Replacing the Chassis Air Filter Installing the Air Filter ...
Page 220: ...ASR 5000 Installation Guide 204 Replacing a Power Filter Unit What to do with the Failed PFU ...
Page 266: ...ASR 5000 Installation Guide 250 Safety Electrical and EMC Certifications Korean EMC ...
Page 270: ...ASR 5000 Installation Guide 254 Environmental Specifications Chassis Air Flow ...