Table 74: Channelized Line Card Active LED States
Troubleshooting
Description
Color
None needed for line cards installed in slots 17 through 23 and
26 through 32 after configuration.
If green for line cards in slots 33 through 39 and 42 through 48,
verify that the corresponding line card installed in the upper-rear
chassis slot is installed properly according to the instructions in
this document.
For example, if this LED is green for a line card in slot 33, verify
that the line card in slot 17 is installed properly.
Card is active
Green
This is normal prior to configuration. Neither the Active or the
Standby LED on the card will be on.
Card in Ready Mode
OR
Card is not receiving
power
OR
Card in Standby Mode
None
Verify that the Run/Fail LED is green. If so, the card is receiving
power and POST test results are positive. If it is off, refer to
Channelized Line Card Run/Fail LED States, on page 161
for
troubleshooting information.
Check the state of the Standby LED. If it is green, the card is in
standby mode. Refer to the
System Administration Guide
for
information on making the card active.
Channelized Line Card Standby LED States
The Standby LED on the channelized line card indicates that software is loaded on the card and it is serving
as a redundant component.
The installed line cards remain in ready mode until their corresponding packet processing card is activated
via configuration. While in ready mode, the Active LED is off. After the packet processing card is activated,
the line card installed in the upper-rear chassis slot behind the packet processing card is activated. The line
card installed in the lower-rear chassis slot behind the packet processing card enters standby mode.
If the LED is not green, use the troubleshooting information in the table to diagnose the problem.
Table 75: Channelized Line Card Standby LED States
Troubleshooting
Description
Color
None needed for line cards installed in slots 33 through 39 and
42 through 48 after configuration.
If green for line cards installed in slots 17 through 23 and 26
through 32, refer to the
System Administration Guide
for
troubleshooting information.
Card is in redundant
mode
Green
ASR 5000 Installation Guide
162
Applying Power and Verifying the Installation
Card-Level LEDs on the Channelized (STM-1/OC-3) Line Card
Summary of Contents for ASR 5000
Page 16: ...ASR 5000 Installation Guide xvi About this Guide Contacting Customer Support ...
Page 64: ...ASR 5000 Installation Guide 48 Installation Procedure Overview Laser Notice ...
Page 100: ...ASR 5000 Installation Guide 84 Line Card Installation Installing the XGLC ...
Page 122: ...ASR 5000 Installation Guide 106 Cabling the Fast Ethernet 10 100 Line Card FLC2 Interfaces ...
Page 206: ...ASR 5000 Installation Guide 190 Removing and Installing SMC PC Cards Removing PC Cards ...
Page 212: ...ASR 5000 Installation Guide 196 Replacing the Chassis Air Filter Installing the Air Filter ...
Page 220: ...ASR 5000 Installation Guide 204 Replacing a Power Filter Unit What to do with the Failed PFU ...
Page 266: ...ASR 5000 Installation Guide 250 Safety Electrical and EMC Certifications Korean EMC ...
Page 270: ...ASR 5000 Installation Guide 254 Environmental Specifications Chassis Air Flow ...