delay trigger (T3/E3)
To configure a time value for the T3 or E3 path delay trigger, use the
delay trigger
command in T3 or E3
configuration mode. To return the command to its default setting, use the
no
form of this command.
delay trigger value
no delay trigger
Syntax Description
Sets the T3 path delay trigger value, in milliseconds. The range is from 0 through 60000.
The default is 2.5 seconds.
value
Command Default
The default is 2.5 seconds.
Command Modes
T3 configuration
E3 configuration
Command History
Modification
Release
This command was introduced.
Release 3.9.0
Support for E3 configuration was added.
Release 4.0.0
Usage Guidelines
To use this command, you must be in a user group associated with a task group that includes appropriate task
IDs. If the user group assignment is preventing you from using a command, contact your AAA administrator
for assistance.
If the timer for the T3 or E3 path delay trigger expires, an alarm is declared.
Task ID
Operations
Task ID
read, write
sonet-sdh
Examples
The following example shows how to set the T3 path delay trigger to 8000 milliseconds:
RP/0/RSP0/CPU0:router(config)#
controller t3 0/4/2/0/1
RP/0/RSP0/CPU0:router(config-t3)#
delay trigger 8000
Cisco ASR 9000 Series Aggregation Services Router Interface and Hardware Component Command Reference,
Release 5.3.x
984
T3, E3, T1, E1 Controller Commands on the Cisco ASR 9000 Series Router
delay trigger (T3/E3)