Description
Field
P-bit errored seconds (PES) is a second with one or
more PCVs, one or more out-of-frame defects, or a
detected incoming AIS. This gauge does not
increment when unavailable seconds are counted.
P-bit Err Secs
P-bit severely errored seconds (PSES) is a second
with 44 or more PCVs, one or more out-of-frame
defects, or a detected incoming AIS. This gauge does
not increment when unavailable seconds are counted.
P-bit Severely Err Secs
Severely errored framing seconds (SEFS) is a second
with one or more out-of-frame defects or a detected
incoming AIS.
Severely Err Framing Secs
The number of unavailable seconds (UAS) is
calculated by counting the number of seconds for
which the interface is unavailable. For more
information, see RFC 1407,
DS3 MIB Variables
.
Unavailable Secs
Line errored seconds (LES) is a second in which one
or more code violations or one or more LOS defects
occurred.
Line Errored Secs
C-bit errored seconds (CES) is a second with one or
more C-bit code violations (CCV), one or more
out-of-frame defects, or a detected incoming AIS.
This gauge is not incremented when UASs are
counted.
C-bit Errored Secs
C-bit severely errored seconds (CSES) is a second
with 44 or more CCVs, one or more out-of-frame
defects, or a detected incoming AIS. This gauge is
not incremented when UASs are counted.
C-bit Severely Errored Secs
Shows the last 15-minute accumulation period.
Total Data (last 24 hours)
Related Commands
Description
Command
Configures an E3 controller and enters E3 configuration mode.
controller e3, on page 972
Cisco ASR 9000 Series Aggregation Services Router Interface and Hardware Component Command Reference,
Release 5.3.x
1041
T3, E3, T1, E1 Controller Commands on the Cisco ASR 9000 Series Router
show controllers e3