threshold sd-ber
To configure the threshold of the Signal Degrade (SD) Bit Error Rate (BER) that is used to trigger a signal
degrade alarm, use the
threshold sd-ber
command in wanphy configuration mode. To return the Signal
Degrade (SD) Bit Error Rate (BER) to the default value, use the no form of this command.
threshold sd-ber exponent
no threshold sd-ber exponent
Syntax Description
Value of 10 raised to the
n
power, where
n
is the exponent of 10, as in10-n. Valid
values are 3 to 9, meaning 10-3 to 10-9.
exponent
Command Default
The default is 6, meaning (10-6).
Command Modes
Wanphy configuration
Command History
Modification
Release
This command was introduced.
Release 5.2.0
Usage Guidelines
Task ID
Operations
Task ID
read, write
interface
Examples
This example shows how to configure sd-ber threshold:
RP/0/RSP0/CPU0:router#
configure
RP/0/RSP0/CPU0:router(config)#
controller wanphy 0/6/1/0
RP/0/RSP0/CPU0:router(config-wanphy)#
threshold sd-ber 9
RP/0/RSP0/CPU0:router(config-wanphy)#
Related Commands
Description
Command
Enables Signal Degrade (SD) Bit Error Rate (BER) reporting.
report sd-ber, on page 1102
Cisco ASR 9000 Series Aggregation Services Router Interface and Hardware Component Command Reference,
Release 5.3.x