clock source (T1/E1)
To set clocking for individual T1 or E1 links, use the
clock source
command in T1 or E1 configuration mode.
To return to the default, use the
no
form of this command.
clock source
{
internal| line
}
no clock source
Syntax Description
Specifies that the clock is generated from the internal clock of the T1 or E1 controller. The
default is internal.
When configuring clocking on a serial link, you need to configure one end to be
internal
and the other end to be
line
. If you configure
internal
clocking on both
ends of a connection, framing slips occur. If you configure
line
clocking on both
ends of a connection, the line does not come up.
Note
internal
Specifies that the clock on this controller derives its clocking from the external source to
which the controller is connected, which is generally the telephone company central office
(CO).
line
Command Default
The default clock source is internal.
Command Modes
T1 configuration
E1 configuration
Command History
Modification
Release
This command was introduced.
Release 3.9.0
Support for E1 configuration mode was added.
Release 4.0.0
Usage Guidelines
To use this command, you must be in a user group associated with a task group that includes appropriate task
IDs. If the user group assignment is preventing you from using a command, contact your AAA administrator
for assistance.
Task ID
Operations
Task ID
read, write
sonet-sdh
Cisco ASR 9000 Series Aggregation Services Router Interface and Hardware Component Command Reference,
Release 5.3.x
966
T3, E3, T1, E1 Controller Commands on the Cisco ASR 9000 Series Router
clock source (T1/E1)