6-38
Cisco Broadband Cable Command Reference Guide
OL-1581-07
Chapter 6 Cable CPE Commands
docsis cvc mfg
docsis cvc mfg
To configure the access start times and organization name for the manufacturer’s code verification
certificate (CVC) to enable the DOCSIS 1.1 secure software download feature on the router, use the
docsis cvc mfg
command in global configuration mode. To delete this information, use the
no
form of
this command.
Cisco uBR905 and Cisco uBR925 cable access routers, and Cisco CVA122 Cable Voice Adapter
docsis cvc mfg
{
codeAccessStart
start-time
|
cvcAccessStart
start-time
|
organization
name
}
no docsis cvc mfg
{
codeAccessStart
start-time
|
cvcAccessStart
start-time
|
organization
name
}
Syntax Description
Defaults
The
codeAccessStart
and
cvcAccessStart
times default to 011219000000Z (midnight on December 19,
2001 Greenwich Mean Time). The organization defaults to Cisco Systems.
Note
Typically, the default values should not be changed unless you are instructed to do so by Cisco TAC or
field service engineers.
Command Modes
Global configuration
Command History
Usage Guidelines
This command configures the access start times and organization name that are required by Appendix D
in the DOCSIS BPI+ specification. The time values are specified as UTC time values in Greenwich Mean
Time, with a two-digit year. If the year is between 50 and 99, it is interpreted as 1950 to 1999. If the year
is between 00 and 49, it is interpreted as 2000 to 2049.
The router uses the
codeAccessStart
value to verify the Code Verification Signature (CVS) that is
affixed to the code file downloaded using the secure software download feature. The router uses the
ccvAccessStart
value to verify the CVC for the code file. The router also uses the
organization
value
to verify that the code file has been created by the proper manufacturer.
codeAccessStart
start-time
Specifies the code Access Start Time as a UTC time value
(
YYMMDDhhmmssZ
) in Greenwich Mean Time.
cvcAccessStart
start-time
Specifies the CVC Access Start Time as a UTC time value
(
YYMMDDhhmmssZ
) in Greenwich Mean Time.
organization
name
Specifies the name of the manufacturer of the code file. Use quotes if the
name
value contains more than one word.
Release
Modification
12.2(15)CZ
This command was introduced on the Cisco uBR905 and Cisco uBR925
cable access routers, and the Cisco CVA122 Cable Voice Adapter.