6-211
Cisco Broadband Cable Command Reference Guide
OL-1581-07
Chapter 6 Cable CPE Commands
debug docsis ssd
If the MSO cosigner’s signature on the software image file cannot be validated using the cosigner’s CVC
on the router, the following messages are displayed:
Co-signer code signature does not validate
Co-signer CVC validation has failed
If the software image was signed either before or after the allowable time range specified as part of the
manufacturer’s CVC, one of the following messages is displayed:
signingTime is before saved codeAccessStart
signingTime is before CVC validNotBefore
signingTime is after CVC validNotAfter
CVC validity start is less than save cvcAccessStart
Related Commands
Command
Description
docsis cvc mfg
Configures the access start times and organization name for the
manufacturer’s code verification certificate (CVC).
docsis cvc mso
Configures the access start times and organization name for the
optional MSO cosigned code verification certificate (CVC).
docsis cvc test
Tests the root CA public key and CM private key that are installed
on the router.