Resolved Caveats
52
Release Notes for Cisco CallManager Release 3.0(10)
78-13493-02
CSCdr74342
DC Directory gets suspended due to file
system error.
The problem was due to the file system
backup utility locking the file using the
win32 LockFile(). LockFile either allows a
shared Read lock or an exclusive Read or
Write lock. If a shared Read lock has been
obtained by a process; no process
(including the one that had first opened the
file) can write to that file. Thus, if a user
attempted to update DCD while the backup
utility held a lock on DCD's DB volumes,
DCD was unable to write to disk and
consequently got into an awkward state.
DCD now obtains an exclusive Read/Write
lock on startup on its DB volumes. This
lock prevents any other process from even
opening the file. Thus, DCD is guaranteed
that no process can deny it (DCD) write
access to its own files once it (DCD)
successfully comes up.
CSCds18156
Symbol Phone create multiple H225D
registered with Line Control
The code has been changed to allow only
one H225D to register with LineControl.
CSCds43712
PerfMon statistics appear to be
unreliable.
The Cisco CallManager software has been
modified so that the PerfMon statistics
appear correctly.
CSCds43792
Sending Disconnect with cause equals
an unallocated number.
The protocol violation on inbound call was
fixed. According to Q.931 standard,
Cisco CallManager shall send RELEASE
COMPLETE instead of DISCONNECT
when unassigned number is received in the
SETUP message.
CSCds46180
Slow SDL timer Service using call load
of 2.25 cps and IVR
Internal data structures that kept track of
call information were not being cleaned up
correctly which lead to some inefficiencies
over time.
Table 6
Cisco CallManager Release 3.0(6) Resolved Caveats (continued)
DDTS Number Summary
Explanation