Removing the Access Point from Service
When removing an access point from service, make sure you remove power from the access point before
opening the cover and disconnecting the input wiring. When removing the wiring, the ground connection
should be the last to be disconnected.
Conducting Periodic Inspections
The access point should be inspected periodically to ensure normal and airtight operation in the hazardous
location environment.
Table 6: Periodic Inspection Table, on page 47
lists the inspection routines and their
periodicity.
Table 6: Periodic Inspection Table
Periodicity
Inspection Routine
Every 3
years
Inspect O-ring seals and exterior electrical connections for aging, corrosion, and low ground
resistance.
Every 5
years
Inspect cover and liquid-tight adapter gaskets for airtightness.
Conducting Periodic Cleaning
The access point is designed to not require periodic cleaning.
Cisco Catalyst IW6300 Heavy Duty Series Access Point Hardware Installation Guide
47