Maximum Weight
Module
17 lbs.
Power Cassette (AC/DC)
15 lbs.
Facility Power Entry Module (FPEM) (AC/DC)
4 lbs.
Fan Module
85 lbs.
13RU Chassis Estimated Weight (with midplanes and
Bus Bar)
429 lbs.
13RU Loaded Chassis Estimated Weight (maximum)
1
117 lbs. with Power Cassette Module and FPEM (recommended configuration during installation)
Table 7: Card Slot Power Allocation
Maximum Power Allocated (Watts)
Module
930
Supervisor Slots
120
Supervisor PIC Slots
530
SSI Card Slots
60
SSI PIC Slots
170
Fan Module
150
Bus Bar + Midplane Loss
7820
cBR-8 Total Power Allocation (power to Bus Bar
from FPEM)
9000
cBR-8 Facility Power Requirement
Table 8: Chassis System Module Overall Dimensional Envelopes
Envelope Size (width x height x depth)
Module
17.24” x 2.75” x 19.99”
Supervisor Card
11.80” x 2.75” x 7.82”
Supervisor PIC
17.24” x 1.48” x 19.99”
SSI Card
11.80” x 1.48” x 7.82”
SSI PIC
5.16” x 3.50” x 8.39”
Fan Module
17.45” x 3.85” x 10.08”
AC FPEM
17.45” x 3.85” x 10.08”
DC FPEM
4.00” x 1.60 x 16.94”
AC Power Supply Module
Cisco Converged Broadband Routers Hardware Installation Guide
14
What is a Cisco cBR Series Converged Broadband Router
Field Replaceable Units