Figure 46: Routing the Fiber-Optic Cables Connected to the Supervisor PIC
—
Option 3
Cable tie
3
Strap-down clip
1
Supervisor PIC cable management bracket
4
Fiber-optic cable bundle in flexible conduit
2
Step 2
Perform the following for the RJ-45 cables connected to the Supervisor PIC:
•
If you are using a chassis-mounted snap-on plastic fiber/cable routing guide, route the RJ-45 cables through the
lower slot of the snap-on plastic fiber/cable routing guide and then through the lower slot of the Supervisor PIC
cable management bracket. Secure the cable bundle using cable ties.
•
If you are using a chassis-mounted cable strap-down clip without the snap-on plastic fiber/cable routing guide,
route the RJ-45 cables through the lower slot of the Supervisor PIC cable management bracket. Secure the cable
bundle to the lower tie down point on the strap-down clip using a cable tie.
Cisco Converged Broadband Routers Hardware Installation Guide
57
Installing the Supervisor in the Cisco cBR Chassis
Cable Management for the Supervisor PIC in the Cisco cBR Chassis