background image

Models may differ within the CBS 350 series and this is just a representation of a model within the series.

Note

• Console port with RJ-45 and mini-USB connectors. The console connects a serial cable to a computer

serial port so that it can be configured using a terminal emulation program.

• USB Port—The USB port connects the switch to a USB device so that you can save and restore the

configuration files, firmware images, and SYSLOG files through the connected USB device.

• RJ-45 Ethernet Ports—The RJ-45 Ethernet ports connect network devices, such as computers, printers,

and access points, to the switch.

• SFP+ Port (if present)—The small form-factor pluggable plus (SFP+) are connection points for modules

so that the switch can link to other switches. These ports are also commonly referred to as mini 10GigaBit
Interface Converter ports. The term SFP+ is used in this guide.

• The SFP+ ports are compatible with the following Cisco SFP 1G optical modules MGBSX1, MGBLX1,

MGBLH1, MGBT1, as well as other brands.

• The Cisco SFP+ 10G optical modules that are supported in the Cisco switches are: SFP-10G-SR,

SFP-10G-LR, SFP-10G-SR-S, and SFP-10G-LR-S.

• The Cisco SFP+ Copper Cable modules that are supported in the Cisco switches are: SFP-H10GB-CU1M,

SFP-H10GB-CU3M, and SFP-H10GB-CU5M.

• Small form-factor pluggable (SFP) ports are connection points for modules, so the switch can link to

other switches.

• Some SFP interfaces are shared with one other RJ-45 port, called a combo port. When the SFP is active,

the adjacent RJ-45 port is disabled.

• The LEDs of the corresponding RJ-45 port flash green to respond to the SFP interface traffic.

• Reset button is used to reset or reboot the switch. To reboot the switch, press the Reset button for less

than 10 seconds.

Front Panel LEDs

The following are the global LEDs found on the devices:

• System—(Green) The LED lights steady when the switch is powered on, and flashes when booting,

performing self-tests, or acquiring an IP address. If the LED flashes Amber, the switch has detected a
hardware or firmware failure, and/or a configuration file error.

• System LED - Every 20 seconds, the System LED will flash according to unit ID of the member unit.

• Flash = LED going off and then on again.

• According to unit ID of the unit. This means

• Unit 1 (if not active) - system LED will flash 1 time

• Unit 2 (if not active) - system LED will flash 2 times

• Unit 3 - system LED will flash 3 times

Get To Know Your Switch

8

Get To Know Your Switch

Front Panel LEDs

Summary of Contents for CBS 350 Series

Page 1: ...ns The advanced features make these switches the ideal choice for aggregation access or server room switches for any business looking for a reliable solution in an affordable price range Before You Begin Before you begin installing your device ensure that the following items are available RJ 45 Ethernet cables for connecting network devices A category 6a and higher cable is required for 10G ports ...

Page 2: ...aviest devices on the bottom A top heavy rack is likely to be unstable and might tip over Caution To install the switch into a 19 inch standard chassis Step 1 Place one of the supplied brackets on the side of the switch so that the four holes of the brackets align to the screw holes and then use the four supplied screws to secure it Step 2 Repeat the previous step to attach the other bracket to th...

Page 3: ... Caution To wall mount a 24 port switch using brackets Step 1 Attach a 19 inch bracket to one side of the switch Step 2 Repeat the previous step to attach the other bracket to the opposite side of the switch Step 3 After the brackets are securely attached mount the switch with the front panel facing down Make sure that the switch is attached securely to wall studs or to a firmly attached plywood m...

Page 4: ...l Step 5 Use a 0 144 inch 3 7 mm or a 27 drill bit to drill a 1 2 inch 12 7 mm hole in the two screw template slots Step 6 Insert two screws in the slots on the screw template and tighten them until they touch the top of the screw template Installing the mounting screws on the wall Figure 3 Installing the mounting screws on the wall Step 7 Remove the screw template from the wall Step 8 Place the s...

Page 5: ...the module or cable plug in If the port speed is configured as auto then the module plugged into these two ports will need to have the same speed capability otherwise the switch will not be able to form as a stack with multiple units Danger The switch can only be stacked without Mesh topology The switches in the same stack are connected together through their stack ports Depending on the type of s...

Page 6: ...BS350 8P E 2G AF AT TPS2388 8 Port Gigabit PoE Managed Switch CBS350 8FP 2G AF AT TPS2388 8 Port Gigabit PoE Managed Switch CBS350 8FP E 2G AF AT 2 TPS2388 16 Port Gigabit PoE Managed Switch CBS350 16P 2G AF AT 2 TPS2388 16 Port Gigabit PoE Managed Switch CBS350 16P E 2G AF AT 2 TPS2388 16 Port Gigabit PoE Managed Switch CBS350 16FP 2G AF AT 3 TPS2388 24 Port Gigabit PoE Managed Switch CBS350 24P ...

Page 7: ...attaching PSE including other PoE switches as a legacy PD Even though PoE switches are PSE and as such should be powered by AC they could be powered up as a legacy PD by another PSE due to false detection When this happens the PoE switch may not operate properly and may not be able to properly supply power to its attaching PDs To prevent false detection you should disable PoE on the ports on the P...

Page 8: ...P 10G LR S The Cisco SFP Copper Cable modules that are supported in the Cisco switches are SFP H10GB CU1M SFP H10GB CU3M and SFP H10GB CU5M Small form factor pluggable SFP ports are connection points for modules so the switch can link to other switches Some SFP interfaces are shared with one other RJ 45 port called a combo port When the SFP is active the adjacent RJ 45 port is disabled The LEDs of...

Page 9: ...ffic SFP if present Green Located on the right of a 10G port The LED lights steady when a connection is made through the shared port and flashes when the port is passing traffic Configuring Switches The switch can be accessed and managed by two different methods over your IP network using the web based interface or by using the switch s command line interface through the console port Using the con...

Page 10: ...y and search for IP Addressing Note Step 4 Open a web browser window Step 5 Enter the switch IP address in the address bar and press Enter For example http 192 168 1 254 Step 6 When the login page appears choose the language that you prefer to use in the web based interface and enter the username and password The default username is cisco The default password is cisco Usernames and passwords are b...

Page 11: ...ork set the IP address type on the switch to Static and change the static IP address and subnet mask to match your network topology Failure to do so may result in multiple switches using the same factory default IP address of 192 168 1 254 Note Console access also provides additional interfaces for debug access which are not available via the web interface These debug access interfaces are intende...

Page 12: ... mode a page level message will be displayed to the user e g there are 2 radius server configured but in basic mode only a single server can be displayed or there is 802 1X port authentication with time range configured but time range is not visible in basic mode When switching from one mode to another any configuration which was made on the page without Apply is deleted Management Buttons The fol...

Page 13: ...g each entry individually it is possible to modify one entry and then copy the selected entry to multiple entries as described below 1 Select the entry to be copied Click Copy Settings to display 2 Enter the destination entry numbers in the to field 3 Click Apply to save the changes and click Close to return to the main page After selecting an entry in the table click Delete to remove Click to dis...

Page 14: ...pies the Startup Configuration file type to the Running Configuration and sets the device parameters according to the data in the Running Configuration Displays the name of the user logged on to the device The default username is cisco The default password is cisco Username Displays the host name assigned in the System Settings page If the host name is longer than 20 character only the first 20 ch...

Page 15: ...en a SYSLOG message above the critical severity level is logged Click the icon to open the RAM Memory page After you access this page the SYSLOG Alert Status icon is no longer displayed To display the page when there is not an active SYSLOG message Click Status and Statistics View Log RAM Memory Get To Know Your Switch 15 Get To Know Your Switch Application Header ...

Page 16: ...Get To Know Your Switch 16 Get To Know Your Switch Application Header ...