C-2
Cisco CGS 2520 Hardware Installation Guide
OL-31444-01
Appendix C Configuring the Switch with the CLI Setup Program
Accessing the CLI Through the Console Port
Figure C-1
Connecting the Console Cable
Step 3
Configure the baud rate and character format of the PC or terminal to match the console port
characteristics:
•
9600 baud
•
8 data bits
•
1 stop bit
•
No parity
•
None (flow control)
Step 4
Connect power to the switch as described in the
“Power Supply Module Installation” section on
page 3-2
.
Step 5
The PC or terminal displays the bootloader sequence. Press
Enter
to display the setup prompt. Follow
the steps in the
“Completing the Setup Program” section on page C-7
.
1
RJ-45 console port
2
Console cable (RJ-45-to-DB-9 adapter cable)
2075
3
6
2
1
1