Step 3
Tighten the thumb screws on both sides of the SSD bay.
Step 4
Check the SSD LED to make sure the SSD is seated properly and functioning. See
for a
description of the SSD LED.
Install the FIPS Opacity Shield in a Two-Post Rack
Because the FIPS opacity shield covers the serial number on the chassis, the CO should copy the serial number
and store it in a secure place. The serial number is needed when you call Cisco TAC.
Note
Before you begin
This procedure should be performed only by the Crypto Officer (CO).
Caution
You need the following items to install the FIPS opacity shield:
• #1 Phillips screwdriver
• The following items from the FIPS kit (part number 800-105495-01):
• One FIPS opacity shield (part number 69-100612-01)
• Two cable management brackets (part number 700-117013-01)
• Eight Phillips 8-32x.375"L screws (part number 48-0629-01) used to attach the FIPS opacity shield
to the cable management brackets
• Ten Tamper Evidence Labels (TEL) (part number 47-25553-01)
The TELs are made of a special thin gauge vinyl with self-adhesive backing.
Once the CO attaches them on the chassis, any attempt to open the chassis damages
the TELs or the chassis cover. Because the TELs have nonrepeated serial numbers,
the CO can inspect them for damage and compare them against the applied serial
numbers to verify whether the chassis has been tampered with. TELs with curled
corners, rips, and slices indicate tampering. The word “FIPS” or “OPEN” may
appear if the label has been peeled back.
Note
Step 1
Copy the serial number and store in a secure place. To find the serial number, see Serial Number Location.
Step 2
Perform the steps described in
Rack-Mount the Chassis Using Brackets
including installing the cable management
bracket (Step 2).
Step 3
Connect the cables to the ports. Make sure that the cables have enough slack to route them through the cable mounting
brackets.
Cisco Firepower 1100 Series Hardware Installation Guide
36
Installation, Maintenance, and Upgrade
Install the FIPS Opacity Shield in a Two-Post Rack