Fans
The Firepower 2110 and 2120 have 4 fixed fans.
The Firepower 2130 and 2140 have a removable fan tray with three + one redundant fans that are hot swappable.
The fan tray is installed in the rear of the chassis. Any one fan can fail indefinitely and the system continues
to function. When a fan fails, the remaining fans automatically spin up to full speed.
The fan LED is located on the front of the chassis.
For More Information
•
See
Front Panel LEDs, on page 9
for the location and description of the fan LED.
•
See
Remove and Replace the Fan Tray, on page 54
for the procedure for removing and replacing the
fan tray.
SSDs
The Firepower 2110 and 2120 have two SSD slots. These models ship with one 100-GB SSD installed in slot
1. The Firepower 2130 and 2140 have two SSD slots. These models ship with one 200-GB SSD installed in
slot 1.
You can use the second SSD slot to upgrade to the MSP. The MSP MUST be installed in the second slot. The
MSP stores threat detection results for use in future analysis. It supports the Advanced Malware Protection
(AMP) software feature. It is used as both storage and as the Malware application repository. RAID is not
supported.
You cannot swap SSDs between different Firepower platforms. For example, you cannot use a 4100 series
SSD in a 2100 series security appliance.
Caution
The 100-GB SSD is restricted to the 2110 and 2120 models. The 200-GB SSD is restricted to the 2130
and 2140 models. Do not mix them.
Note
Although the hardware supports hot swapping for the SSDs, the software does not, so you must power down
the chassis before removing and replacing them.
For More Information
•
See
Front Panel, on page 6
for the location and description of the SSD LEDs on the front panel.
•
See
Remove and Replace the SSD, on page 45
for the procedure for removing and replacing the SSD.
Supported SFP/SFP+ Transceivers
Take note of the following warnings:
Cisco Firepower 2100 Series Hardware Installation Guide
20
Overview
Fans