Off
On
Power supply module failure
Includes over voltage, over current,
over temperature, and fan failure
Off
1 Hz blinking
Power supply module warning
events
Power supply continues to operate
(high temperature, high power, and
slow fan)
1 Hz blinking
Off
Power present
3.3VSB on (power supply module
off)
On
Off
Power supply module ok and on
Fan Modules
The Firepower 4100 security appliance requires six fan modules, which are hot-swappable. They are installed
in the rear of the chassis. The system supports operation with a single fan failure (N+1 fan redundancy), but
do not run the system for an extended amount of time without all fan modules installed. Keep removal and
replacement time at three minutes. Remove and replace one fan module at a time.
If you remove a fan or a fan fails, the other fans operate at full speed, which can be noisy.
The fan modules are numbered left to right, for example, FAN1, FAN2, FAN3, FAN4, FAN5, and FAN6.
See
Remove and Replace the Fan Module, on page 62
for the procedure for removing and replacing the fan
module.
The following figure shows the location of the fan LED.
Figure 13: Fan LED
Cisco Firepower 4100 Series Hardware Installation Guide
20
Overview
Fan Modules