2 -6
Firepower 7000 Series Hardware Installation Guide
Chapter 2 Hardware Specifications
Firepower 7000 Series Devices
Table 2-9
Firepower 70xx Family Physical and Environmental Parameters
Parameter
Description
Form factor
1U, half rack width
Dimensions (D x W x H)
Single chassis: 12.49 in. x 7.89 in. x 1.66 in. (31.74 cm x 20.04 cm x 4.21 cm)
2-Chassis Tray: 25.05 in. x 17.24 in. x 1.73 in. (63.62 cm x 43.8 cm x 4.44 cm)
Chassis weight
maximum installed
Chassis: 7 lbs (3.17 kg)
Single chassis and power supply in tray: 17.7 lbs (8.03 kg)
Double chassis and power supplies in single tray: 24.7 lbs (11.2 kg)
Copper 1000BASE-T
Gigabit copper Ethernet bypass-capable interfaces in a paired configuration
Cable and distance: Cat5E at 50 m
Power supply
200 W AC power supply
Voltage: 100 VAC to 240 VAC nominal (90 VAC to 264 VAC maximum)
Current: 2A maximum over the full range
Frequency range: 50/60 Hz nominal (47 Hz to 63 Hz maximum)
Solid-state drive (SSD)
240GB 2.5-inch SSD
Operating temperature
7010/20/30
32°F to 104°F (0°C to 40°C)
7050
23°F to 104°F (-5°C to 40°C)
Non-operating temperature 7010/20/30
-4°F to 158°F (-20°C to 70°C)
7050
14°F to 140°F (-10°C to 60°C)
Operating humidity
7010/20/30
5% to 95%, non-condensing
Operation beyond these limits is not guaranteed and not recommended.
7050
5% to 85%, non-condensing
Operation beyond these limits is not guaranteed and not recommended.
Non-operating humidity
7010/20/30
0% to 95%, non-condensing
7050
0% to 85%, non-condensing
Store the unit below the maximum non-condensing relative humidity. Acclimate below
maximum operating humidity at least 48 hours prior to placing the unit in service.
Altitude
0 ft (sea level) to 5905 ft (0 m to 1800 m)
Cooling requirements
682 BTU/hour
You must provide sufficient cooling to maintain the appliance within its required operating
temperature range. Failure to do this may cause a malfunction or damage to the appliance.
Acoustic noise
53 dBA when idle. 62 dBA at full processor load
Operating shock
No errors with half a sine wave shock of 5G (with 11 ms duration)
Airflow
20 ft
3
(0.57 m
3
) per minute