2 -13
Firepower 7000 Series Hardware Installation Guide
Chapter 2 Hardware Specifications
Firepower 7000 Series Devices
Firepower 7115, 7125, and AMP7150
The Firepower 7115, 7125, and AMP7150 devices, part of the 71xx Family, are delivered with four-port
copper interfaces with configurable bypass capability, and eight hot-swappable small form-factor
pluggable (SFP) ports without bypass capability. To ensure compatibility, use only Cisco SFP
transceivers.
Note
The Firepower AMP7150 has many of the same form factors as the Firepower 7115 and 7125, but has
been optimized to take advantage of the Firepower System’s AMP for Networks capabilities.
See the following sections for more information:
•
Firepower 7115, 7125, and AMP7150 Chassis Front View, page 2-14
•
Firepower 7115, 7125, and AMP7150 Chassis Rear View, page 2-18
•
Firepower 7115, 7125, and AMP7150 Physical and Environmental Parameters, page 2-20
Power supply
450 W dual redundant (1+1) AC power supplies
Voltage: 100 VAC to 240 VAC nominal (85 VAC to 264 VAC maximum)
Current: 3A maximum for 90 VAC to 132 VAC, per supply
1.5A maximum for 187 VAC to 264 VAC, per supply
Frequency range: 47 Hz to 63 Hz
Solid-state drive (SSD)
240GB 2.5-inch SSD.
Operating temperature
41
o
F to 104
o
F (5
o
C to 40
o
C)
Non-operating temperature -29
o
F to 158
o
F (-20
o
C to 70
o
C)
Operating humidity
5% to 85% non-condensing
Non-operating humidity
5% to 90%, non-condensing with a maximum wet bulb of 82
o
F (28
o
C) at temperatures from 77
o
F
to 95
o
F (25
o
C to 35
o
C)
Store the unit below 95% non-condensing relative humidity. Acclimate below maximum
operating humidity at least 48 hours before placing the unit in service.
Altitude
0ft (sea level) to 5905 ft (0 m to 1800 m)
Cooling requirements
900 BTU/hour
You must provide sufficient cooling to maintain the appliance within its required operating
temperature range. Failure to do this may cause a malfunction or damage to the appliance.
Acoustic noise
64 dBA at full processor load, normal fan operation
Meets GR-63-CORE 4.6 Acoustic Noise
Operating shock
Complies with Bellecore GR-63-CORE standards
Airflow
140 ft
3
(3.9 m
3
) per minute
Airflow through the appliance enters at the front and exits at the rear with no side ventilation.
Table 2-21
Firepower 7110 and 7120 Physical and Environmental Parameters (continued)
Parameter
Description