Monitor Setup Options
4004834 Rev D
91
Displaying Alarm Status
Follow these steps to display the list of active alarms.
1
Press
OPTIONS
. The Alarm Status screen appears.
Alarm at 11:51:03
Input1 loss of signal
Notes:
Each alarm description appears for approximately 1 second before displaying
the next alarm. If no alarms are active, a
No Active Alarms
message appears.
See
Troubleshooting Alarm Messages
for detailed descriptions of alarms.
2
Press
ENTER
. The default screen appears.
Viewing the Session Count
The Session Count screen displays the count of all active sessions for the selected RF
output. Follow these steps to view the total number of active sessions.
1
Press
OPTIONS
twice. The Session Count screen appears.
CH1 Session Count
10
Note:
The session count for the GoQAM will differ from the session count on the
DNCS if the GoQAM does not find needed MPEG programs within MPEG
Program Specific Information (PSI). By design, the GoQAM responds positively
to a session setup request even if the requested MPEG program is not present on
the input transport stream.
2
Press
RF SEL
to view the session count for each channel (CH1 or CH2).
3
Press
ENTER
to return to the default screen.
Viewing the Program Count
The Program Count screen displays the encrypted programs currently running on
the selected RF output. Follow these steps to view the program count for an RF
module.
1
Press
OPTIONS
three times. The Program Count screen appears.
CH1 Program Count
5
2
Press
RF SEL
to view the program count for each channel (CH1 or CH2).
3
Press
ENTER
to return to the default screen.
Summary of Contents for GoQAM
Page 1: ...GoQAM Modulator RF Output and IF Output Hardware Installation and Operation Guide ...
Page 2: ......
Page 8: ......
Page 14: ......
Page 30: ......
Page 52: ......
Page 67: ...Provision GoQAMs on the DNCS 4004834 Rev D 51 ...
Page 68: ......
Page 116: ......
Page 138: ......
Page 164: ......
Page 176: ......