Appendix A
Technical Specifications
150
4004834 Rev D
Installation and Operation Requirements
This section contains tables that define specifications specific to installing and
operating the GoQAM.
Power Requirements Table
The following table describes the power specifications for the GoQAM.
Item
Specification
Supply Voltage
90V to 130V AC @ 47 to 63 Hz (AC unit)
180V to 264V AC @ 47 to 63 Hz (AC unit)
–42V to –57V DC (DC unit)
Fuses
4.0 A SLO BLO 250V (AC unit)
6.3 A SLO BLO 250V (DC unit)
Line Frequency
47 to 63 Hz (AC unit only)
Power Required
RF GoQAM: 155 VA (typical)
IF GoQAM: 85 VA (typical)
Power Dissipated
RF GoQAM: 151 Watts (typical)
IF GoQAM: 80 Watts (typical)
In Rush Current
35 amps maximum, Vin = 130V AC (AC unit)
75 amps maximum, Vin = 264V AC (AC unit)
15 amps maximum, Vin = -57V DC (DC unit)
Rack Requirements Table
Item
Specification
Rack Mount Type
EIA RS-310
Height
1.75 in./44.45 mm
Width
19 in./482.6 mm
Depth
22.5 in./571.5 mm
Weight
13.5 lb./5.4 kg