A-4
Cisco IE 3000 Switch Hardware Installation Guide
Appendix A Technical Specifications
Table A-3
Technical Specifications for the Power Converter and AC-Input Power Supplies
Environmental Ranges
Operating temperature
–29 to 165°F (–34 to 74°C)
Storage temperature
–40 to 185°F (–40 to 85°C)
Operating altitude
Up to 13,000 ft (3962 m)
Storage altitude
Up to 40,000 ft (12,192 m)
Thermal spacing
3.54 in. (90 mm) exposed side
4.13 in. (105 mm) top and bottom
Power Requirements
AC input voltages
Range: 85–264 VAC at 47–63 Hz
Nominal: 115 VAC at 60 Hz or 230 VAC at 50 Hz
Maximum AC power input
current
0.75 A @ 230 VAC and 50 Hz or
1.25 A @ 115 VAC and 60 Hz
DC input voltages
Range: 88-300VDC
Nominal: 125 VDC or 250 VDC
Maximum DC input current
0.75 A at 220 VDC or
1.25 A at 150 VDC
DC output voltage
+24 VDC
DC output current
2.1 A (max)
Hold-up time
Minimum 20 ms at full load and 115 VAC
Physical Dimensions
Weight
1.4 lb (0.63 kg)
Dimensions (W x D x H)
2 x 4.62 x 5.81 in. (50.8 x 117.5 x 147.6 mm)
Note
Width includes the cosmetic end-caps. Height does not
include the panel mount brackets. Depth is the distance
from the rail.
Table A-4
Hazardous Locations Standards
Specification Standards
Hazardous Locations
ANSI/ISA 12.12.01-2011
UL 60079-0, 5th Ed, 2009-10-21
IEC 60079-15, 3rd Ed, 2009-7-17
CSA C22.2 No. 213-M1987
CAN/CSA E60079-15: 02
EN 60079-0:2009
EN 60079-15:2010
IEC 60079-0 4th Edition
IEC 60079-15 5th Edition