B-38
Cisco IE 3000 Switch Hardware Installation Guide
Appendix B Installation In a Hazardous Environment
Installing the Switch
Figure B-26
Installing the Switch on a Rack
.
After the switch is mounted in the rack, connect the power and alarm wires, as described in the
“Connecting Power and Alarm Circuits” section on page B-39
.
For instructions on how to remove the switch from a rack, see the
“Removing the Switch from a DIN
Rail or a Rack” section on page B-38
Removing the Switch from a DIN Rail or a Rack
To remove the switch from a DIN rail or a rack, follow these steps:
Step 1
Ensure that power is removed from the switch, and disconnect all cables and connectors from the front
panel of the switch.
Step 2
Use a tool such as a flathead screw driver to press in the space next to the tab on each of the latches and
turn the screw driver clockwise. See
Step 3
Push the DIN rail latches at the top of the switch up and the latches at the bottom of the switch down.
Pull the switch out, and release the switch from the DIN rail. See
.