background image

2-47

Cisco IE 3000 Switch Hardware Installation Guide

Chapter 2      Switch Installation

Connecting Destination Ports

Connecting to 100BASE-FX Ports

Follow these steps to connect a fiber-optic cable to an Cisco IEM-3000-8FM expansion module:

Warning

Class 1 laser product. Statement 1008

Caution

Do not remove the rubber plugs from the SFF module port or the rubber caps from the fiber-optic cable 
until you are ready to connect the cable. The plugs and caps protect the SFF module ports and cables 
from contamination.

Before connecting to the SFF module port, be sure that you understand the port and cabling stipulations 
in the

 

“Preparing for Installation” section on page 2-1

. See the 

“Cable and Adapter Specifications” 

section on page C-5

 

for information about the LC connector on the SFF module.

Step 1

Remove the rubber plugs from the module port and fiber-optic cable, and store them for future use. 

Step 2

Insert one end of the fiber-optic cable into the SFP module port. Se

Figure 2-37

.

Figure 2-37

Connecting to a Fiber-Optic SFP Module Port

Step 3

Insert the other cable end into a fiber-optic receptacle on a target device.

Step 4

Observe the port status LED.

The LED turns green when the switch and the target device have an established link.

The LED turns amber while the STP discovers the network topology and searches for loops. This process 
takes about 30 seconds, and then the port LED turns green.

1

LC connector

1

202031

Summary of Contents for IE 3000

Page 1: ...as more than 200 offices worldwide Addresses phone numbers and fax numbers are listed on the Cisco website at www cisco com go offices Cisco IE 3000 Switch Hardware Installation Guide First Published March 2013 Last Updated December 23 2014 ...

Page 2: ...turning it off If the interference stops it was probably caused by the Cisco equipment or one of its peripheral devices If the equipment causes interference to radio or television reception try to correct the interference by using one or more of the following measures Turn the television or radio antenna until the interference stops Move the equipment to one side or the other of the television or ...

Page 3: ...100 Ports 1 8 Dual Purpose Ports 1 8 SFP Modules 1 8 100BASE FX Ports 1 10 100BASE X Ports 1 10 PoE Ports 1 10 Power and Relay Connector 1 10 Console Port 1 11 LEDs 1 11 Setup LED 1 14 System LED 1 14 Alarm LED 1 14 Power Status LED 1 15 10 100 Port Status LEDs 1 15 100Base FX Port Status LEDs 1 16 Dual Purpose Port LEDs 1 16 100BASE X SFP Port LEDs 1 17 PoE Status LED 1 17 10 100BASE T PoE and No...

Page 4: ...and DC Power 2 15 Grounding the Switch 2 15 Wiring the DC Power Source 2 18 Attach the Power and Relay Connector to the Switch 2 23 Attaching DC Power to the PoE Expansion Modules 2 23 Running POST 2 25 Applying Power to the Switch 2 25 Verify POST Results 2 25 Disconnect Power 2 26 Installing the Switch 2 26 Installing the Switch on a DIN Rail 2 27 Installing the Switch on the Wall 2 31 Installin...

Page 5: ...ting the Switch to the AC Input Power Supply 2 56 Attaching the Power Supply to the Switch 2 56 Installing the AC input Power Supply on a DIN Rail Wall or Rack Adapter 2 56 Connecting the DC Power Clip 2 57 Connecting the AC Input Power Supply to an AC Power Source 2 57 Connecting the AC Power Cord to the Power Supply 2 58 Where to Go Next 2 58 C H A P T E R 3 Troubleshooting 3 1 Diagnosing Proble...

Page 6: ...4 Verifying Switch Operation B 15 Connecting a PC or a Terminal to the Console Port B 16 Connecting the Protective Ground and DC Power B 17 Grounding the Switch B 18 Wiring the DC Power Source B 20 Attach the Power and Relay Connector to the Switch B 25 Attaching DC Power to the PoE Expansion Modules B 26 Running POST B 27 Applying Power to the Switch B 27 Verify POST Results B 28 Disconnect Power...

Page 7: ... 59 Applying Power to the Power Converter B 61 Connecting the Switch to the AC Input Power Supply B 61 Attaching the Power Supply to the Switch B 61 Installing the AC input Power Supply on a DIN Rail Wall or Rack Adapter B 62 Connecting the DC Power Clip B 62 Connecting the AC Input Power Supply to an AC Power Source B 63 Connecting the AC Power Cord to the Power Supply B 63 Where to Go Next B 64 ...

Page 8: ...ying a Crossover Cable C 10 Adapter Pinouts C 10 A P P E N D I X D Configuring the Switch with the CLI Based Setup Program D 1 Accessing the CLI from the Console Port D 1 Entering the Initial Configuration Information D 2 IP Settings D 2 Completing the Setup Program D 2 ...

Page 9: ...e switch getting started guide the switch software configuration guide the switch command reference and the switch system message guide on the Cisco comTechnical Support and Documentation home page For information about the standard Cisco IOS Release 12 1 or 12 2 commands see the Cisco IOS documentation set from the Cisco com home page at Technical Support and Documentation Documentation On the Ci...

Page 10: ...Started Guide Regulatory Compliance and Safety Information for the Cisco IE 3000 Switch Release Notes for the Cisco IE 3000 Switch Cisco IE 3000 Switch Software Configuration Guide Cisco IE 3000 Switch Command Reference Cisco IE 3000 Switch System Message Guide Device manager online help available on the switch Cisco Small Form Factor Pluggable Modules Installation Notes These compatibility matrix...

Page 11: ...elligent transportation systems ITSs substations and other deployments in harsh environments You can connect these switches to office networking devices like Cisco IP Phones Cisco Wireless Access Points workstations and other devices such as servers routers and other switches In industrial environments you can connect any Ethernet enabled industrial communication devices including programmable log...

Page 12: ...00 4TC 4 10 100BASE T Ethernet ports and 2 dual purpose ports each with a 10 100 1000BASE T copper port and an SFP small form factor pluggable module slot Cisco IE 3000 8TC 8 10 100BASE T Ethernet ports and 2 dual purpose ports Cisco IE 3000 4TC E 4 10 100BASE T Ethernet ports and 2 dual purpose ports supports the IP services software feature set Cisco IE 3000 8TC E 8 10 100BASE T Ethernet ports a...

Page 13: ...o IE 3000 8TC Switch Figure 1 2 Cisco IE 3000 4TC Switch 1 Power and relay connectors 4 10 100 ports 2 Console port 5 Protective ground connection 3 Dual purpose ports 201699 1 5 3 2 4 1 Power and relay connectors 4 10 100 ports 2 Console port 5 Protective ground connection 3 Dual purpose ports 5 3 2 201700 4 1 ...

Page 14: ...itch Hardware Installation Guide Chapter 1 Overview Front Panel Description Figure 1 3 Cisco IEM 3000 8TM Expansion Module Figure 1 4 Cisco IEM 3000 8FM Expansion Module 1 10 100 ports 1 201702 1 100BASE FX ports 1 201701 ...

Page 15: ...tallation Guide Chapter 1 Overview Front Panel Description Figure 1 5 Cisco IEM 3000 4SM Expansion Module Figure 1 6 Cisco IEM 3000 8SM Expansion Module 1 100BASE X SFP ports 1 2 3 4 1 345668 1 100BASE X SFP ports 1 5 2 6 3 7 4 8 1 345667 ...

Page 16: ...sco IE 3000 Switch Hardware Installation Guide Chapter 1 Overview Front Panel Description Figure 1 7 Cisco IEM 3000 4PC PoE Expansion Module 1 DC Input terminal block 3 PoE ports 2 POE STATUS LED 346705 2 3 1 ...

Page 17: ...tch Hardware Installation Guide Chapter 1 Overview Front Panel Description Figure 1 8 Cisco IEM 3000 4PC 4TC PoE Expansion Module 1 10 100 Non PoE ports 3 POE STATUS LED 2 DC Input terminal block 4 PoE ports 346704 2 3 1 4 ...

Page 18: ...d cable type for copper Ethernet connections and configures the interfaces accordingly For configuration information for this feature see the switch software configuration guide or the switch command reference Dual Purpose Ports A dual purpose port can be configured as either a 10 100 1000 port or as an SFP module port Only one port can be active at a time If both ports are connected the SFP modul...

Page 19: ...Rugged and Industrial SFPs 40 to 140 F 40 to 60 C GLC SX MM RGD GLC LX SM RGD GLC FE 100LX RGD GLC FE 100FX RGD GLC ZX SM RGD GLC BX40 D I with digital optical monitoring DOM support GLC BX40 DA I with DOM support GLC BX80 D I with DOM support GLC BX40 U I with DOM support GLC BX80 U I with DOM support Commercial SFPs 32 to 113 F 0 to 45 C GLC BX D with DOM support GLC BX U with DOM support GLC FE...

Page 20: ...nel connectors One connector provides primary DC power supply A and the major alarm signal and a second connector supply B provides secondary power and the minor alarm signal The two connectors are physically identical and are in the upper left side of the front panel See Figure 1 2 The switch accessory pack includes the mating power and relay connectors These connectors provide screw terminals fo...

Page 21: ...l Support Console Port You can connect a switch to a PC through the console port and the supplied RJ 45 to DB 9 adapter cable If you want to connect a switch to a terminal you need to provide an RJ 45 to DB 25 female DTE adapter You can order a kit part number ACS DSBUASYN with that adapter from Cisco Systems For console port and adapter pinout information see the Two Twisted Pair Cable Pinouts se...

Page 22: ...l Description Figure 1 10 LEDs on the Cisco IE 3000 Switch Figure 1 11 LEDs on the Cisco IEM 3000 8TM Module 1 Express setup button 5 Dual purpose uplink port LED 2 System LED 6 Pwr B LED 3 Alarm LED 7 Pwr A LED 4 Setup LED 8 Port LED 201703 8 5 6 7 3 4 2 1 1 10 100 port LED 201706 1 ...

Page 23: ...escription Figure 1 12 LEDs on the Cisco IEM 3000 8FM Module Figure 1 13 LEDs on the Cisco IEM 3000 8SM Module Note The port numbering sequence is the same for the IEM 3000 4SM expansion module 1 100BASE FX port LEDs 1 201705 1 100BASE X port LEDs 1 5 2 6 3 7 4 8 3 7 4 8 3 7 4 8 1 345669 ...

Page 24: ... LED Table 1 5 lists the alarm LED colors and their meanings Table 1 3 Setup LED Color Setup Status Off dark Switch is configured as a managed switch Solid green Switch is in initial setup Blinking green Switch is in initial setup in recovery or initial setup is incomplete Solid red Switch failed to start initial setup or recovery because there is no available switch port to which to connect the m...

Page 25: ...n the switch if the power input drops below the low valid level The power status LEDs only show that power is present if the voltage at the switch input exceeds the valid level The difference or hysteresis ensures that the power status LEDs do not oscillate at values near 18 V For information about the power LED colors during the power on self test POST see the Verifying Switch Operation section o...

Page 26: ...nd errors such as excessive collisions CRC errors and alignment and jabber errors are monitored for a link fault indication Solid amber Port is not forwarding Port was disabled by management an address violation or STP Note After a port is reconfigured the port LED can remain amber for up to 30 seconds while STP checks the switch for possible loops Table 1 7 10 100 Port Status LEDs continued Color...

Page 27: ...eiving power from an AC power source the port LED is off even if the powered device is connected to the switch port Green PoE is on The port LED is green only when the switch port is providing power Alternating green and amber PoE is denied because providing power to the powered device will exceed the power capacity of the expansion module Flashing amber PoE is off due to a fault Caution Noncompli...

Page 28: ...lash memory card that makes it possible to replace a failed switch without reconfiguring the new switch The slot for the compact flash memory card is on the bottom of the switch See Figure 1 15 Note For more information on inserting and removing the compact flash memory card see the Installing or Removing the Compact Flash Memory Card section on page 2 12 ...

Page 29: ...00 by calling Cisco Technical Support Rear Panel Description The rear panel of the switch modules and power converter have latches for installation on either a DIN rail or a wall See Figure 1 16 The latches slide outward to position the switch over a DIN rail and slide inward to secure the switch to a DIN rail The feet stabilize the switch when it is mounted on the wall 1 201832 Bottom of switch ...

Page 30: ... switch and up to two modules The power converter is mounted on the side of a switch and provides power to the switch through a preassembled power cable Note The power converter PWR IE3000 AC is sold separately You can get a replacement power cable PWR IE3000 CLP by calling Cisco Technical Support For installation and connection procedures for the power converter see the Connecting the Switch to t...

Page 31: ... AC cable PWR IE50W AC IEC An AC input power supply with an IEC C14 appliance connector for a detachable AC power cord Figure 1 18 shows the AC input power supply The power supply is designed to operate from source AC range of 85 to 264 VAC 115 VAC nominal at 60 Hz or 230 VAC nominal at 50 Hz and provides 24 VDC to one switch and up to two modules The power supply attaches to the side of a switch ...

Page 32: ... html For information on starting the Cisco Network Assistant application see the Getting Started with Cisco Network Assistant guide on Cisco com Device Manager You can use the device manager which is in the switch memory to manage individual and standalone switches This web interface offers quick configuration and monitoring You can access the device manager from anywhere in your network through ...

Page 33: ...ple Network Management Protocol SNMP platform See the CiscoView documentation for more information SNMP network management You can manage switches from a SNMP compatible management station that is running platforms such as HP OpenView or SunNet Manager The switch supports a comprehensive set of Management Information Base MIB extensions and four Remote Monitoring RMON groups See the switch softwar...

Page 34: ...1 24 Cisco IE 3000 Switch Hardware Installation Guide Chapter 1 Overview Network Configurations ...

Page 35: ...der Preparing for Installation page 2 1 Adding Modules to the Switch page 2 5 Installing or Removing the Compact Flash Memory Card page 2 12 Verifying Switch Operation page 2 13 Installing the Switch page 2 26 Connecting Power and Alarm Circuits page 2 36 Connecting Destination Ports page 2 40 Connecting the Switch to the Power Converter page 2 48 Connecting the Switch to the AC Input Power Supply...

Page 36: ...allation in restricted access areas A restricted access area can be accessed only through the use of a special tool lock and key or other means of security Statement 1017 Warning This equipment must be grounded Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor Contact the appropriate electrical inspection authority or an electrician ...

Page 37: ...ies ensuring electromagnetic compatibility in other environments due to conducted as well as radiated disturbance This equipment is supplied as open type equipment It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts The enclo...

Page 38: ...vice cannot exceed 6562 ft 2 km For 100BASE X SFP ports in the IEM 3000 4SM and the IEM 3000 8SM expansion modules the cable length is dependent on the type of SFP installed in the port Operating environment is within the ranges listed in Appendix A Technical Specifications Clearance to front and rear panels meets these conditions Front panel LEDs can be easily read Access to ports is sufficient f...

Page 39: ...dapter from Cisco For multimode MM connections you can connect a 100BASE FX port to a port on a target device by using an dual LC connector You can order a kit containing four spare latches DINCLP IE3000 from Cisco Adding Modules to the Switch The Cisco IE 3000 4TC or the Cisco IE 3000 8TC switch can operate as standalone devices with four or eight Fast Ethernet ports respectively To increase the ...

Page 40: ...00BASE T 4 10 100FE 8 100FX 8 10 100BASE T 4 Cisco IEM 3000 4PC Cisco IEM 3000 8SM 10 100FE 4 100BASE X 8 10 100BASE T 4 10 100FE 8 100BASE X 8 10 100BASE T 4 Cisco IEM 3000 4PC Cisco IEM 3000 8TM 10 100FE 12 10 100BASE T 4 10 100FE 16 10 100BASE T 4 Cisco IEM 3000 4PC 4TC 10 100FE 4 10 100BASE T 8 10 100FE 8 10 100BASE T 8 Cisco IEM 3000 4PC 4TC Cisco IEM 3000 4PC 10 100FE 4 10 100BASE T 12 10 10...

Page 41: ...Cisco IEM 3000 4SM Cisco IEM 3000 8SM 10 100FE 4 100BASE X 12 10 100FE 8 100BASE X 12 Cisco IEM 3000 4SM Cisco IEM 3000 8TM 10 100FE 12 100BASE X 4 10 100FE 16 100BASE X 4 Cisco IEM 3000 8FM 10 100FE 4 100FX 8 10 100FE 8 100FX 8 Cisco IEM 3000 8SM 10 100FE 4 100BASE X 8 10 100FE 8 100BASE X 8 Cisco IEM 3000 8TM 10 100FE 12 10 100FE 16 Cisco IEM 3000 8TM Cisco IEM 3000 4PC 10 100FE 12 10 100BASE T ...

Page 42: ...ontained in Table 2 1 Note The switch and expansion module sample combinations illustrated in Figure 2 1 show an IE 3000 4TC switch The same sample combinations could also be used with the Cisco IE 3000 8TC switch Note Due to power constraints a configuration that includes either IE 3000 switch and two IEM 3000 8SM expansion modules is not supported Also no expansion modules can be attached to the...

Page 43: ...000 4TC switch with Cisco IEM 3000 8TM and Cisco IEM 3000 8FM expansion modules 12 FE and 8 FX ports 3 Cisco IE 3000 4TC switch with one Cisco IEM 3000 8TM expansion modules 12 FE ports 2 Cisco IE 3000 4TC switch with one Cisco IEM 3000 8FM expansion module 4 FE and 8 FX ports 4 Cisco IE 3000 4TC switch with two Cisco IEM 3000 8TM expansion modules 20 FE ports 1 2 3 4 201827 ...

Page 44: ...o connect the expansion modules to the switch follow these steps Step 1 Remove the side panel of the switch by firmly grasping both sides of it in the middle and pulling it outward If necessary use a screwdriver to pry open the side panel See Figure 2 2 Figure 2 2 Opening the Side Panel of the Cisco IE 3000 8TC Switch Step 2 Remove the EMI protective cover from the interface connector on the switc...

Page 45: ...2 4 Push down the lower module latches at the bottom of the switch and the expansion module Figure 2 4 Pushing the Module Latches Up Step 4 Align the connectors on the switch and the module and slide the switch and the module together to make the connection See Figure 2 5 Figure 2 5 Connecting the Switch and the Module Step 5 Push the upper module latches down and the lower latches up See Figure 2...

Page 46: ...M 3000 4PC 4TC PoE expansion module to the switch you must also connect the expansion modules to source DC Source DC can come from either the PWR IE65W PC DC a DC input power supply the PWR IE65W PC AC an AC input power supply or from site source DC however the site source power voltage must be 48 54VDC Installing or Removing the Compact Flash Memory Card The switches store Cisco IOS software imag...

Page 47: ...it in an antistatic bag to protect it from static discharge To install a card slide it into the slot and press it firmly in place The card is keyed so that you cannot insert it the wrong way Verifying Switch Operation Before installing the switch in its final location power on the switch and verify that the switch passes the power on self test POST These sections describe the steps required to con...

Page 48: ...al or Procomm Plus makes communication between the switch and your PC or terminal possible during the POST Follow these steps to connect the PC or terminal to the switch Step 1 Make sure that your terminal emulation software is configured to communicate with the switch using hardware flow control Step 2 Configure the baud rate and data format of the PC or terminal to match these console port defau...

Page 49: ...pport See the Obtaining Documentation Obtaining Support and Security Guidelines section on page viii Obtain these necessary tools and equipment Ratcheting torque flathead screwdriver that can exert up to 15 inch pounds in lb of torque Ring terminal lug such as Thomas Bett part number 10RCR or equivalent Crimping tool such as Thomas Bett part number WT2000 ERG 2001 or equivalent 10 gauge copper gro...

Page 50: ... number 10 to 12 AWG wire such as Thomas Bett part number 10RCR or equivalent Note Use at least a 4mm2 conductor to connect to the external grounding screw Step 1 Use a standard Phillips screwdriver or a ratcheting torque screwdriver with a Phillips head to remove the ground screw from the front panel of the switch Store the ground screw for later use Step 2 Use a wire stripping tool to strip the ...

Page 51: ...crew opening on the front panel Step 6 Use a ratcheting torque screwdriver to tighten the ground screw and ring terminal lug to the switch front panel to 8 5 in lb The torque should not exceed 8 5 in lb 0 9 Nm See Figure 2 11 Figure 2 11 Attaching the Ground Lug Screw Step 7 Attach the other end of the ground wire to a grounded bare metal surface such as a ground bus a grounded DIN rail or a groun...

Page 52: ...must comply with local and national electrical codes Statement 1074 Warning Before performing any of the following procedures ensure that power is removed from the DC circuit Statement 1003 Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Statement 1030 Caution You must connect the switch only to a DC input power source that has an input s...

Page 53: ...oming from each DC input power source to 0 25 inch 6 3 mm 0 02 inch 0 5 mm Do not strip more than 0 27 inch 6 8 mm of insulation from the wire Stripping more than the recommended amount of wire can leave exposed wire from the power and relay connector after installation Figure 2 13 Stripping the Power Connection Wire Step 5 Insert the exposed part of the positive wire into the connection labeled V...

Page 54: ... 6 Use a ratcheting torque flathead screwdriver to torque the power and relay connector captive screws above the installed wire leads to 2 2 in lb 0 25 Nm See Figure 2 15 Caution Do not over torque the power and relay connector captive screws The torque should not exceed 2 2 in lb 0 25 Nm 1 Power source positive connection 2 Power source return connection 202028 RT A V A 1 2 ...

Page 55: ...he other end of the return wire the one connected to RT to the return terminal on the DC power source When you are testing the switch one power connection is sufficient If you are installing the switch and are using a second power source repeat Step 4 through Step 7 using a second power and relay connector Figure 2 16 shows the completed DC input wiring on a power and relay connector for a primary...

Page 56: ...Switch Operation section on page 2 13 1 Power source A positive connection 5 Power source B positive connection 2 Power source A return connection 6 Power source B return connection 3 External device 1 relay wire connection 7 External device 2 relay wire connection 4 External device 1 relay wire connection 8 External device 2 relay wire connection 201818 RT A V A RT A V A 1 2 3 4 5 6 7 8 1 Power s...

Page 57: ...e repeat this procedure for the second power and relay connector Pwr B which installs just below the primary power connector Pwr A When you are installing the switch secure the wires coming from the power and relay connector so that they cannot be disturbed by casual contact For example use tie wraps to secure the wires to the rack Attaching DC Power to the PoE Expansion Modules If your switch con...

Page 58: ... appropriate type wire size and color code for your country Step 3 Using a wire stripping tool strip both ends of the twisted pair wires to 0 25 inch 6 3 mm 0 02 inch 0 5 mm Do not strip more than 0 27 inch 6 8 mm of insulation from the wires Step 4 Attach the twisted pair wire leads into the site source DC positive and negative connectors Verify that only insulated wire extends from the connector...

Page 59: ...expansion module or from a separate DC power supply PWR IE65W PC DC or PWR IE65W PC AC If your switch configuration consists of two PoE expansion modules you must connect each PoE expansion module to a separate power supply For instructions on how to connect the DC input power supply to the PoE expansion module refer to the Cisco IE 3000 65 W DC Input Power Supply Installation Note available on ci...

Page 60: ...ch in a Rack Warning This equipment is supplied as open type equipment It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts The interior of the enclosure must be accessible only by the use of a tool The enclosure must meet IP ...

Page 61: ... the switch as a standalone device on the DIN rail or with the expansion modules already connected You must connect expansion modules to the switch before installing the switch on the DIN rail To connect the modules to the switch follow the steps described in the Adding Modules to the Switch section on page 2 5 The illustrations in this procedure show how to install the switch as a standalone devi...

Page 62: ...tallation Installing the Switch To attach the switch to a DIN rail follow these steps Step 1 Use a flathead screwdriver to press in the space next to the tab on each of the latches and turn the screw driver clockwise See Figure 2 19 Figure 2 19 Unlock the Switch Latch 270302 ...

Page 63: ...on Installing the Switch Step 2 Push out on the DIN rail latches See Figure 2 20 Figure 2 20 Pushing the DIN Rail Latches Out Step 3 Position the rear panel of the switch directly in front of the DIN rail making sure that the DIN rail fits in the space between the two latches 201828 ...

Page 64: ...the switch is over the DIN rail See Figure 2 21 Figure 2 21 Pushing the DIN Rail Latches In Note If you are using a 15 mm DIN rail rotate all of the feet see Figure 2 21 to the extended positions Otherwise rotate all of the feet to the recessed positions Figure 2 22 shows the two DIN rails You can use either the 7 5 mm or the 15 mm DIN rail 201829 ...

Page 65: ...ow to remove the switch from a DIN rail see the Removing the Switch from a DIN Rail or a Rack section on page 2 35 Installing the Switch on the Wall To attach the switch to a wall or a panel follow these steps Warning Read the wall mounting instructions carefully before beginning installation Failure to use the correct hardware or to follow the correct procedures could result in a hazardous situat...

Page 66: ...ch Hardware Installation Guide Chapter 2 Switch Installation Installing the Switch Step 1 If the DIN rail latches are pushed out push in the DIN rail latches See Figure 2 23 Figure 2 23 Pushing the DIN Rail Latches In 202370 ...

Page 67: ...tep 4 Place a number 10 screw that you provide through each DIN rail latch and screw them into the wall After the switch is mounted on the wall or panel connect the power and alarm wires as described in the Connecting Power and Alarm Circuits section on page 2 36 Installing the Switch in a Rack You can use an optional DIN rail adapter kit available through Cisco part number STK RACKMNT 2955 to mou...

Page 68: ...l on the Rack Step 2 Follow the steps described in the Installing the Switch on a DIN Rail page 27 Warning To prevent bodily injury when mounting or servicing this unit in a rack you must take special precautions to ensure that the system remains stable The following guidelines are provided to ensure your safety This unit should be mounted at the bottom of the rack if it is the only unit in the ra...

Page 69: ...on on page 2 35 Removing the Switch from a DIN Rail or a Rack To remove the switch from a DIN rail or a rack follow these steps Step 1 Ensure that power is removed from the switch and disconnect all cables and connectors from the front panel of the switch Step 2 Use a tool such as a flathead screw driver to press in the space next to the tab on each of the latches and turn the screw driver clockwi...

Page 70: ...ective Ground and DC Power page 2 36 Wiring the External Alarms page 2 37 Wiring the Protective Ground and DC Power Note The switch can use either a dual or single positive DC input 24V 48V or a single negative DC input 24V 48V Dual negative DC inputs are not supported For instructions on grounding the switch and connecting the DC power see the Connecting the Protective Ground and DC Power section...

Page 71: ...part number 9318 To wire the switch to an external alarm device follow these steps Step 1 Measure two strands of twisted pair wire 18 to 20 AWG long enough to connect to the external alarm device Step 2 Use a wire stripper to remove the casing from both ends of each wire to 0 25 inch 6 3 mm 0 02 inch 0 5 mm Do not strip more than 0 27 inch 6 8 mm of insulation from the wires Stripping more than th...

Page 72: ...ver torque the power and relay connector captive screws The torque should not exceed 2 2 in lb 0 25 Nm Figure 2 29 Torquing the Power and Relay Connector Captive Screws Step 5 Repeat Step 1 through Step 4 to insert the input and output wires of an additional external alarm device into the second power and relay connector 202030 RT A V A ...

Page 73: ...panel 1 Power source A positive connection 5 Power source B positive connection 2 Power source A return connection 6 Power source B return connection 3 External device 1 relay wire major alarm connection 7 External device 2 relay wire minor alarm connection 4 External device 1 relay wire major alarm connection 8 External device 2 relay wire minor alarm connection 201820 RT A V A RT A V A 1 2 3 4 5...

Page 74: ...s that do not autonegotiate or that have their speed and duplex parameters manually set can reduce performance or result in no linkage To maximize performance choose one of these methods for configuring the Ethernet ports Let the ports autonegotiate both speed and duplex Set the port speed and duplex parameters on both ends of the connection Caution To prevent electrostatic discharge ESD damage fo...

Page 75: ...cabling problems Step 3 Reconfigure and reboot the connected device if necessary Step 4 Repeat Steps 1 through 3 to connect each device Installing and Removing SFP Transceivers These sections describe how to install and remove SFP transceivers SFP transceivers are inserted into SFP transceiver ports on the front of the switch or the Cisco IEM 3000 4SM or Cisco IEM 3000 8SM expansion modules These ...

Page 76: ... fiber optic cables attached to it because of the potential damage to the cables the cable connector or the optical interfaces in the SFP module Disconnect all cables before removing or installing an SFP transceiver Removing and installing an SFP transceiver can shorten its useful life Do not remove and insert SFP transceiver more often than is absolutely necessary Figure 2 32 SFP Transceiver with...

Page 77: ...for future use Insert the LC network cable connector into the SFP transceiver Removing SFP Transceivers from Module Ports To remove an SFP transceiver from a module port follow these steps Step 1 Attach an ESD preventive wrist strap to your wrist and to a grounded bare metal surface Step 2 Disconnect the network cable LC connector from the SFP transceiver Step 3 Immediately insert a dust plug into...

Page 78: ... a Dual Purpose Port section on page 2 45 For instructions on how to install or remove an SFP transceiver see the Installing and Removing SFP Transceivers section on page 2 41 Follow these steps to connect a fiber optic cable to an SFP transceiver Warning Class 1 laser product Statement 1008 Caution Do not remove the rubber plugs from the SFP transceiver port or the rubber caps from the fiber opti...

Page 79: ...e network topology and searches for loops This process takes about 30 seconds and then the port LED turns green If the LED is off the target device might not be turned on there might be a cable problem or there might be a problem with the adapter installed in the target device See Chapter 3 Troubleshooting for solutions to cabling problems Step 5 If necessary reconfigure and restart the switch or ...

Page 80: ...install an SFP transceiver into the module port and connect a cable to the SFP transceiver See Figure 2 36 For more information about RJ 45 connections SFP transceivers and optical connections see the Connecting to 10 100 and 10 100 1000 Ports section on page 2 40 the Installing and Removing SFP Transceivers section on page 2 41 and the Connecting to SFP Transceivers section on page 2 44 Figure 2 ...

Page 81: ...tions in the Preparing for Installation section on page 2 1 See the Cable and Adapter Specifications section on page C 5 for information about the LC connector on the SFF module Step 1 Remove the rubber plugs from the module port and fiber optic cable and store them for future use Step 2 Insert one end of the fiber optic cable into the SFP module port See Figure 2 37 Figure 2 37 Connecting to a Fi...

Page 82: ... the IEEE 802 3at standard PoE which provides up to 30 W of power per port To allow 4 PoE ports the following command line is required when using over 65 W power input to the expansion module power inline wattage mod max 4 130 watts Connecting the Switch to the Power Converter The Cisco IE 3000 switch can be used with an optional AC DC power converter PWR IE3000 AC These sections describe the step...

Page 83: ... of it in the middle and pulling it outward If necessary use a screwdriver to open the side panel See Figure 2 38 Figure 2 38 Opening the Left Side Panel of the Switch Step 2 Push the upper modules latches at the top of the switch and the power converter up and the lower module latches at the bottom of the switch and the power converter down See Figure 2 39 Figure 2 39 Pushing the Module Latches U...

Page 84: ...ment It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts The interior of the enclosure must be accessible only by the use of a tool The enclosure must meet IP 54 or NEMA type 4 minimum enclosure rating standards Statement 106...

Page 85: ...Do not over torque the power and relay connector captive screws The torque should not exceed 2 2 in lb 0 25 Nm Connecting the Power Converter to an AC Power Source These sections describe the steps required to connect the power converter to an AC power source Preparing the AC Power Cord page 2 51 Connecting the AC Power Cord to the Power Converter page 2 52 Preparing the AC Power Cord To connect t...

Page 86: ...otected by a dedicated two pole circuit breaker Caution Do not insert the power cord into the AC outlet until the process of wiring the line neutral and ground connections has been completed To connect the AC power cord to the power converter follow these steps Step 1 Remove the plastic cover from the input power terminals and set it aside See Figure 2 42 Figure 2 42 AC DC Power Input Terminal Blo...

Page 87: ...ads into the terminal block line and neutral connections See Figure 2 43 Make sure that you cannot see any wire lead Ensure that only wire with insulation extends from the connectors Step 5 Tighten the line and neutral terminal block screws Note The torque should not exceed 2 2 in lb 0 25 Nm Step 6 Replace the plastic cover over the terminal block Step 7 Connect the other end of the AC power cord ...

Page 88: ...ir copper wire long enough to connect the power converter to the DC power source For DC connections from the power converter to the DC source use 18 AWG twisted pair copper wire such as Belden part number 9344 or the equivalent Step 3 Using a 18 gauge wire stripping tool strip the ground wire and both ends of the twisted pair wires to 0 25 inch 6 3 mm 0 02 inch 0 5 mm Do not strip more than 0 27 i...

Page 89: ...labeled number 1 in Figure 2 44 lead into the neutral wire connection and the wire labeled number 2 in Figure 2 44 lead into the line wire connection Ensure that only wire with insulation extends from the connectors See Figure 2 44 Step 8 Tighten the line and neutral terminal block screws Note The torque should not exceed 10 in lb Step 9 Connect the red wire to the positive pole of the DC power so...

Page 90: ...upply to the Switch Follow these steps to connect the AC input power supply to the switch Step 1 Remove the left side panel of the switch by firmly grasping both sides of it in the middle and pulling it outward If necessary use a screwdriver to open the side panel See Figure 2 38 for a illustration of how to remove the switch side panel Step 2 Push the upper modules latches at the top of the switc...

Page 91: ...switch module Step 1 Locate the DC power clip in the AC input power supply accessory kit Step 2 Position the power clip so that the two pin connector is over the power converter and the four pin connector is over the switch Pwr A connector and then slide the power clip into these two connectors Step 3 Use a ratcheting torque flathead screwdriver to tighten the captive screw to 2 2 in lb 0 25 Nm Ca...

Page 92: ...nal block screw Note The torque should not exceed 2 2 in lb 0 25 Nm Step 5 Insert the line and neutral wire leads into the terminal block line and neutral connections Make sure that you cannot see any wire lead Ensure that only wire with insulation extends from the connectors Step 6 Tighten the line and neutral terminal block screws Note The torque should not exceed 2 2 in lb 0 25 Nm Step 7 Replac...

Page 93: ...to Go Next Use the CLI to configure the switch as an individual switch from the console See the switch command reference on Cisco com for information about using the CLI Start an SNMP application such as the CiscoView application Start the Common Industrial Protocol CIP management tool You can manage an entire industrial automation system with the CIP based tools ...

Page 94: ...2 60 Cisco IE 3000 Switch Hardware Installation Guide Chapter 2 Start the Common Industrial Protocol CIP management tool You can manage an entire industrial Where to Go Next ...

Page 95: ...application for details Verify Switch POST Results As the switch powers on it begins the POST a series of tests that runs automatically to ensure that the switch functions properly It might take several minutes for the switch to complete POST POST starts with LED tests that cycles once through the System Alarm Setup Pwr A and Pwr B LEDs While POST proceeds the System LED blinks green and all the o...

Page 96: ... port constantly flaps loses and regains link Exchange the copper or fiber optic cable with a known good cable Look for broken bent or missing pins on cable connectors Rule out any bad patch panel connections or media convertors between the source and destination If possible bypass the patch panel or eliminate faulty media convertors fiber optic to copper Try the cable in another port or interface...

Page 97: ...quirements for the switch Check these items Bad or wrong SFP module Exchange the suspect module with a known good module Verify that the module is supported on this platform The switch release notes on Cisco com list the SFP modules that the switch supports Use the show interfaces privileged EXEC command to verify the port or module error disabled disabled or shutdown status Re enable the port if ...

Page 98: ...ck sequence FCS or late collisions errors this might indicate a speed or duplex mismatch A common issue with speed and duplex is when the duplex settings are mismatched between two switches between a switch and a router or between the switch and a workstation or server This can happen when manually setting the speed and duplex or from autonegotiation issues between the two devices A mismatch occur...

Page 99: ...word on the switch 1 Power off the switch 2 Power on the switch and at the same time press and hold down the Express Setup button until all the system LEDs turn red 3 Release the Express Setup button and the switch continues to boot After the switch restarts continue to run Express Setup The switch now behaves like an unconfigured switch You can configure the switch by using Express Setup as descr...

Page 100: ... and Figure 3 2 to find the serial number on your switch or module See Figure 3 3 to find the serial number on your power converter You can also use the show version privileged EXEC command to get the switch serial number Figure 3 1 Serial Number Location for the Cisco IE 3000 4TC and the Cisco IE 3000 8TC Switch Figure 3 2 Serial Number Location for the Cisco IEM 3000 8TM and the Cisco IEM 3000 8...

Page 101: ...lation Guide Chapter 3 Troubleshooting Finding the Switch Serial Number Figure 3 3 Serial Number Location for the Cisco PWR IE3000 AC Power Converter DC OK 24V 2 1A Rtn Out Pwr Out 125 250V 1 25A MAX 100 240V 50 60Hz N L SN XXXNNNNXXXX 205092 ...

Page 102: ...3 8 Cisco IE 3000 Switch Hardware Installation Guide Chapter 3 Troubleshooting Finding the Switch Serial Number ...

Page 103: ... types Table A 1 describes three different environments and the operating temperature for each of the environments Note The safety certifications apply only to ambient temperatures under 140 F 60 C However the Cisco IE 3000 switch can function in the substation and traffic signal installations under the environmental conditions shown in Table A 1 Table A 1 Operating Temperature for the Cisco IE 30...

Page 104: ...put voltage Cisco IE 3000 8TC and Cisco IE 3000 4TC Range 18 to 60 VDC Nominal 24 or 48 VDC The DC input power supply is an SELV circuit and it can only be connected to another SELV circuit Switch models with PoE cabability require an additional power input connection to power the PoE ports This connection requires 48 54 VDC 2 4A PoE mode 48VDC nominal 44 57 VDC absolute range PoE mode 54VDC nomin...

Page 105: ...IEM 3000 8TM 2 05 lb 0 93 kg Cisco IEM 3000 4SM 2 5 lb 1 14 kg Cisco IEM 3000 8SM 3 04 lb 1 38 kg Cisco IEM 3000 4PC 2 4 lb 1 08 kg Cisco IEM 3000 4PC 4TC 2 6 lb 1 16 kg Dimensions W x D x H Cisco IE 3000 8TC and Cisco IE 3000 4TC 6 x 4 4 x 5 8 in 15 4 x 11 2 x 14 7 cm Cisco IEM 3000 8TM IEM 3000 8FM IEM 3000 4SM IEM 3000 8SM IEM 3000 4PC and IEM 3000 4PC 4TC 3 6 x 4 4 x 5 8 in 9 1 x 11 2 x 14 7 c...

Page 106: ...VAC and 50 Hz or 1 25 A 115 VAC and 60 Hz DC input voltages Range 88 300VDC Nominal 125 VDC or 250 VDC Maximum DC input current 0 75 A at 220 VDC or 1 25 A at 150 VDC DC output voltage 24 VDC DC output current 2 1 A max Hold up time Minimum 20 ms at full load and 115 VAC Physical Dimensions Weight 1 4 lb 0 63 kg Dimensions W x D x H 2 x 4 62 x 5 81 in 50 8 x 117 5 x 147 6 mm Note Width includes th...

Page 107: ...aring for Installation page B 1 Adding Modules to the Switch page B 7 Installing or Removing the Compact Flash Memory Card page B 14 Verifying Switch Operation page B 15 Installing the Switch page B 29 Connecting Power and Alarm Circuits page B 39 Connecting Destination Ports page B 44 Connecting the Switch to the Power Converter page B 52 Where to Go Next page B 64 Preparing for Installation This...

Page 108: ...d for installation in restricted access areas A restricted access area can be accessed only through the use of a special tool lock and key or other means of security Statement 1017 Warning This equipment must be grounded Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor Contact the appropriate electrical inspection authority or an el...

Page 109: ...ocation the DC power source could be located away from the vicinity of the switch Before performing any of the following procedures locate the DC circuit to ensure that the power is removed and cannot be turned on accidentally or verify that the area is nonhazardous before proceeding Statement 1059 Warning This equipment is supplied as open type equipment It must be mounted within an enclosure tha...

Page 110: ... following information applies when operating this equipment in hazardous locations English Products marked Class I Div 2 GP A B C D are suitable for use in Class I Division 2 Groups A B C D Hazardous Locations and nonhazardous locations only Each product is supplied with markings on the rating nameplate indicating the hazardous location temperature code When combining products within a system the...

Page 111: ...pment according to IEC CISPR Publication 11 Without appropriate precautions there may be potential difficulties ensuring electromagnetic compatibility in other environments due to conducted as well as radiated disturbance This equipment is supplied as open type equipment It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be presen...

Page 112: ...intermittent grounding Secure the DIN rail to the mounting surface approximately every 7 8 in 200 mm and use end anchors appropriately When determining where to place the switch observe these guidelines Before installing the switch first verify that the switch is operational by powering it on and running POST Follow the procedures in the Verifying Switch Operation section on page 2 13 For 10 100 p...

Page 113: ...ation for the Cisco IE 3000 Switch Regulatory Compliance and Safety Information for the Cisco IE 3000 Switch safety warnings translated in German Two power and relay connectors RJ 45 to DB 9 console port adapter cable Note To connect the switch functional ground you need a ring terminal lug such as Thomas Bett part number RC10 14 or equivalent If you want to connect a terminal to the switch consol...

Page 114: ...Switch 10 100FE 4 10 100FE 8 Cisco IEM 3000 4PC 10 100FE 4 10 100BASE T 4 10 100FE 8 10 100BASE T 4 Cisco IEM 3000 4PC Cisco IEM 3000 4PC 10 100FE 4 10 100BASE T 8 10 100FE 8 10 100BASE T 8 Cisco IEM 3000 4PC Cisco IEM 3000 4PC 4TC 10 100FE 4 10 100BASE T 12 10 100FE 8 10 100BASE T2 12 Cisco IEM 3000 4PC Cisco IEM 3000 4SM 10 100FE 4 100BASE X 4 10 100BASE T 4 10 100FE 8 100BASE X 4 10 100BASE T 4...

Page 115: ...E T 4 Cisco IEM 3000 4SM Cisco IEM 3000 8FM 10 100FE 4 100FX 8 100BASE X 4 10 100FE 8 100FX 8 100BASE X 4 Cisco IEM 3000 4SM Cisco IEM 3000 8SM 10 100FE 4 100BASE X 12 10 100FE 8 100BASE X 12 Cisco IEM 3000 4SM Cisco IEM 3000 8TM 10 100FE 12 100BASE X 4 10 100FE 16 100BASE X 4 Cisco IEM 3000 8FM 10 100FE 4 100FX 8 10 100FE 8 100FX 8 Cisco IEM 3000 8SM 10 100FE 4 100BASE X 8 10 100FE 8 100BASE X 8 ...

Page 116: ...s not supported Also the only expansion modules that can be attached to the right expansion module 2 of an IEM 3000 8SM expansion module are the IEM 3000 4PC and the IEM 3000 4PC 4TC PoE expansion modules due to the two PoE expansion modules requiring their own dedicated power supply All other expansion modules can not be attached to the right of the IEM 3000 8SM expansion module Cisco IEM 3000 8T...

Page 117: ...s of Expansion Modules 1 IE 3000 4TC switch with IEM 3000 8TM and Cisco IEM 3000 8FM expansion modules 12 FE and 8 FX ports 3 IE 3000 4TC switch with one IEM 3000 8TM expansion modules 12 FE ports 2 IE 3000 4TC switch with one IEM 3000 8FM expansion module 4 FE and 8 FX ports 4 IE 3000 4TC switch with two IEM 3000 8TM expansion modules 20 FE ports 1 2 3 4 201827 ...

Page 118: ...xpansion module To connect the expansion modules to the switch follow these steps Step 1 Remove the side panel by firmly grasping both sides of it in the middle and pulling it outward If necessary use a screwdriver to pry open the side panel See Figure B 2 Figure B 2 Opening the Side Panel of the Cisco IE 3000 8TC Switch Step 2 Remove the EMI protective cover from the interface connector on the sw...

Page 119: ...gure B 4 Push down the lower module latches at the bottom of the switch and the expansion module Figure B 4 Pushing the Module Latches Up Step 4 Align the connectors on the switch and the module and slide the switch and the expansion module together to make the connection See Figure B 5 Figure B 5 Connecting the Switch and the Module Step 5 Push the upper module latches down and the lower latches ...

Page 120: ...mbinations Installing or Removing the Compact Flash Memory Card The switches store Cisco IOS software images and switch configurations on a removable flash memory card You can replace the switch without reconfiguring it The switch ships with the compact flash memory card installed Verify that the card is in place on the bottom of the switch Warning Do not insert or remove the compact flash card wh...

Page 121: ...op and pull it out Place it in an antistatic bag to protect it from static discharge To install a card slide it into the slot and press it firmly in place The card is keyed so that you cannot insert it the wrong way Verifying Switch Operation Before installing the switch in its final location power on the switch and verify that the switch passes the power on self test POST These sections describe ...

Page 122: ...sconnect the console cable with power applied to the switch or any device on the network an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous before proceeding To verify switch operation perform POST on the switch in a nonhazardous location before installation Statement 1065 Follow these steps to con...

Page 123: ...ective ground and DC power to the switch Grounding the Switch page B 18 Wiring the DC Power Source page B 20 Attach the Power and Relay Connector to the Switch page B 25 Note The Cisco IE 3000 switch can be used with an optional AC DC power converter PWR IE3000 AC For instructions on how to connect the power converter to the switch see the Connecting the Switch to the Power Converter section on pa...

Page 124: ...feat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available Statement 1024 Warning This equipment is intended to be grounded to comply with emission and immunity requirements Ensure that the switch functional ground lug i...

Page 125: ...ool crimp the ring terminal to the wire Figure B 10 Crimping the Ring Terminal Step 4 Slide the ground screw through the ring terminal Step 5 Insert the ground screw into the functional ground screw opening on the front panel Step 6 Use a ratcheting torque screwdriver to tighten the ground screw and ring terminal lug to the switch front panel to 8 5 in lb See Figure B 11 1 0 5 in 12 7 mm 0 02 in 0...

Page 126: ...he DC power source Caution This product is intended to be supplied by a Listed Class 2 power source marked with Class 2 and rated from 18 to 60 VDC 0 VDC 2 1 A Warning A readily accessible two poled disconnect device must be incorporated in the fixed wiring Statement 1022 Warning This product relies on the building s installation for short circuit overcurrent protection Ensure that the protective ...

Page 127: ...tional AC DC converter go to the Connecting the Switch to the Power Converter section on page B 52 To wire the switch to a DC input power source follow these steps Step 1 Locate the power and relay connector see Figure B 12 Figure B 12 Power and Relay Connector Step 2 Identify the positive and return DC power connections on the connector The positive DC power connection is labeled V and the return...

Page 128: ...rom a DC input power source can conduct harmful levels of electricity Be sure that no exposed portion of the DC input power source wire extends from the power and relay connector Statement 122 Figure B 14 Inserting Wires in the Power and Relay Connector Step 6 Use a ratcheting torque flathead screwdriver to torque the power and relay connector captive screws above the installed wire leads to 2 2 i...

Page 129: ...he one connected to V to the positive terminal on the DC power source and connect the other end of the return wire the one connected to RT to the return terminal on the DC power source When you are testing the switch one power connection is sufficient If you are installing the switch and are using a second power source repeat Step 4 through Step 7 using a second power and relay connector 1 Power a...

Page 130: ... Wiring the External Alarms section on page B 41 Otherwise go to the Verifying Switch Operation section on page B 15 1 Power source A positive connection 5 Power source B positive connection 2 Power source A return connection 6 Power source B return connection 3 External device 1 relay wire connection 7 External device 2 relay wire connection 4 External device 1 relay wire connection 8 External de...

Page 131: ...ailure to securely tighten the power and relay connector captive screws can result in an electrical arc if the connector is accidentally removed Statement 1058 Figure B 17 Connecting the Power and Relay Connector to the Switch Step 2 Use a ratcheting torque flathead screwdriver to tighten the captive screws on the sides of the power and relay connector When you are testing the switch one power sou...

Page 132: ...he DC input power supply As an added precaution place the appropriate safety flag and lockout devices at the source power circuit breaker or place a piece of adhesive tape over the circuit breaker handle to prevent accidental power restoration while you are working on the circuit Step 2 Measure a length of twisted pair copper wire long enough to connect the site source DC to the PoE expansion modu...

Page 133: ...odule either IEM 3000 4PC or IEM 3000 4PC 4TC to the switch you must attach DC power directly to the expansion module DC power can be either from site source DC verify that source DC power meets the power input requirements of the expansion module or from a separate DC power supply PWR IE65W PC DC or PWR IE65W PC AC If your switch configuration consists of two PoE expansion modules you must connec...

Page 134: ...g and memory hardware Assuming all tests pass the System LED continues to blink green as the Cisco IOS software image loads If the POST fails the System LED turns red Note POST failures are usually fatal Call Cisco Systems immediately if your switch does not pass POST See the Obtaining Documentation Obtaining Support and Security Guidelines section on page viii ...

Page 135: ...ronmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts The interior of the enclosure must be accessible only by the use of a tool The enclosure must meet IP 54 or NEMA type 4 minimum enclosure rating standards Statement 1063 Warning When used in a Class I Division 2 hazardous location this equipment must be mounted...

Page 136: ...n install the switch as a standalone device on the DIN rail or with the expansion modules already connected You must connect the expansion modules to the switch before installing the switch on the DIN rail To connect the modules to the switch follow the steps described in the Adding Modules to the Switch section on page B 7 The illustrations in this procedure show how to install the switch as a st...

Page 137: ... Environment Installing the Switch To attach the switch to a DIN rail follow these steps Step 1 Use a tool such as a flathead screw driver to press in the space next to the tab on each of the latches and turn the screw driver clockwise See Figure B 19 Figure B 19 Unlock the Switch Latch 270302 ...

Page 138: ...us Environment Installing the Switch Step 2 Push the DIN rail latches out See Figure B 20 Figure B 20 Pushing the DIN Rail Latches Out Step 3 Position the rear panel of the switch directly in front of the DIN rail making sure that the DIN rail fits in the space between the two latches 201828 ...

Page 139: ...s in after the switch is over the DIN rail See Figure B 21 Figure B 21 Pushing the DIN Rail Latches In Note If you are using a 15 mm DIN rail rotate all of the feet see Figure B 21 to the extended positions Otherwise rotate all of the feet to the recessed positions Figure B 22 shows the two DIN rails You can use either the 7 5 mm or the 15 mm DIN rail 201829 ...

Page 140: ...structions on how to remove the switch from a DIN rail see the Removing the Switch from a DIN Rail or a Rack section on page B 38 Installing the Switch on a Wall To attach the switch to a wall or a panel follow these steps Warning Read the wall mounting instructions carefully before beginning installation Failure to use the correct hardware or to follow the correct procedures could result in a haz...

Page 141: ...e Installation Guide Appendix B Installation In a Hazardous Environment Installing the Switch Step 1 If the DIN rail latches are pushed out push in the DIN rail latches See Figure B 23 Figure B 23 Pushing the DIN Rail Latches In 202370 ...

Page 142: ...the Wall Step 4 Place a number 10 screw that you provide through each DIN rail latch and screw them into the wall After the switch is mounted on the wall or panel connect the power and alarm wires as described in the Connecting Power and Alarm Circuits section on page B 39 Installing the Switch in a Rack You can use an optional DIN rail adapter kit available through Cisco part number STK RACKMNT 2...

Page 143: ... Rail on the Rack Step 2 Follow the steps described in the Installing the Switch on a DIN Rail section on page B 30 Warning To prevent bodily injury when mounting or servicing this unit in a rack you must take special precautions to ensure that the system remains stable The following guidelines are provided to ensure your safety This unit should be mounted at the bottom of the rack if it is the on...

Page 144: ...Rack section on page B 38 Removing the Switch from a DIN Rail or a Rack To remove the switch from a DIN rail or a rack follow these steps Step 1 Ensure that power is removed from the switch and disconnect all cables and connectors from the front panel of the switch Step 2 Use a tool such as a flathead screw driver to press in the space next to the tab on each of the latches and turn the screw driv...

Page 145: ...27 Removing the Switch from the DIN Rail Step 4 Remove the switch from the DIN rail Connecting Power and Alarm Circuits After the switch is installed you are ready to connect the DC power and alarm relays Information about the Sealed Relay Device page B 40 Wiring the Protective Ground and DC Power page B 40 Wiring the External Alarms page B 41 201850 ...

Page 146: ...aterial type 2125G Generic name of plastic material liquid crystal polymer Relay Epoxy manufacturer of plastic material Resinous Kasei Co Ltd Designation of material type A 2500BK Generic name of plastic material epoxy resin Sealed Device Relay Model B4GA003Z manufactured by Fujitsu Takamisawa Electric Company Ltd Relay cover manufacturer of plastic material Sumitomo Chemical Co Ltd Designation of...

Page 147: ... must be an isolated source and limited to less than or equal to 24 VDC 1 A Note Wire connections to the power and relay connector must be UL and CSA rated style 1007 or 1569 twisted pair copper appliance wiring material AWM wire such as Belden part number 9318 To wire the switch to an external alarm device follow these steps Step 1 Measure two strands of twisted pair wire 18 to 20 AWG long enough...

Page 148: ... screw above the installed wire leads to 2 2 in lb 0 25 Nm See Figure B 29 for details Caution Do not over torque the power and relay connector captive screws The torque should not exceed 2 2 in lb 0 25 Nm Figure B 29 Torquing the Power and Relay Connector Captive Screws Step 5 Repeat Step 1 through Step 4 to insert the input and output wires of an additional external alarm device into the second ...

Page 149: ...the front panel 1 Power source A positive connection 5 Power source B positive connection 2 Power source A return connection 6 Power source B return connection 3 External device 1 relay wire major alarm connection 7 External device 2 relay wire minor alarm connection 4 External device 1 relay wire major alarm connection 8 External device 2 relay wire minor alarm connection 201820 RT A V A RT A V A...

Page 150: ...o the ports while power is applied to the switch or any device on the network because an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed from the switch and cannot be accidentally be turned on or verify that the area is nonhazardous before proceeding Statement 1070 To maximize performance choose one of these methods for confi...

Page 151: ... does not turn on The device at the other end might not be turned on There might be a cable problem or a problem with the adapter installed in the attached device See Chapter 3 Troubleshooting for solutions to cabling problems Step 3 Reconfigure and reboot the connected device if necessary Step 4 Repeat Steps 1 through 3 to connect each device Installing and Removing SFP Transceivers These section...

Page 152: ...tation on cisco com Installing SFP Transceivers into Module Ports Note This procedure is applicable to SFP ports on either the switches or on the expansion modules Figure B 32 shows an SFP transceiver that has a bale clasp latch Caution We strongly recommend that you do not install or remove the SFP transceiver with fiber optic cables attached to it because of the potential damage to the cables th...

Page 153: ... you are ready to install the network cable remove the dust plugs from both the cable and the SFP transceiver and store them away for future use Insert the LC cable connector into the SFP transceiver Removing SFP Transceivers from Module Ports To remove an SFP transceiver from a module port follow these steps Step 1 Attach an ESD preventive wrist strap to your wrist and to a grounded bare metal su...

Page 154: ...to a Dual Purpose Port section on page B 49 For instructions on how to install or remove an SFP transceiver see the Installing and Removing SFP Transceivers section on page B 45 Follow these steps to connect a fiber optic cable to an SFP transceiver Warning Class 1 laser product Statement 1008 Caution Do not remove the rubber plugs from the SFP transceiver port or the rubber caps from the fiber op...

Page 155: ...ers the network topology and searches for loops This process takes about 30 seconds and then the port LED turns green If the LED is off the target device might not be turned on there might be a cable problem or there might be a problem with the adapter installed in the target device See Chapter 3 Troubleshooting for solutions to cabling problems Step 5 If necessary reconfigure and restart the swit...

Page 156: ...00 1000 port or install an SFP module into the SFP module slot and connect a cable to the SFP module port See Figure B 36 For more information about RJ 45 connections SFP modules and optical connections see the Connecting to 10 100 and 10 100 1000 Ports section on page B 44 the Installing and Removing SFP Transceivers section on page B 45 and the Connecting to SFP Transceivers section on page B 48...

Page 157: ...d cabling stipulations in the Preparing for Installation section on page B 1 See the Cable and Adapter Specifications section on page C 5 for information about the LC connector on the SFP module Step 1 Remove the rubber plugs from the module port and fiber optic cable and store them for future use Step 2 Insert one end of the fiber optic cable into the SFP module port See Figure B 35 Figure B 37 C...

Page 158: ...expansion module ports as PoE you must connect the expansion module directly to the site s source DC The expansion module PoE ports support either the IEEE 802 3af standard PoE which provides up to 15 4 W of power per port 4 ports total or the IEEE 802 3at standard PoE which provides up to 30 W of power per port 2 ports total Connecting the Switch to the Power Converter The Cisco IE 3000 switch ca...

Page 159: ...ment Connecting the Switch to the Power Converter Step 1 Remove the left side panel of the switch by firmly grasping both sides of it in the middle and pulling it outward If necessary use a screwdriver to open the side panel See Figure B 38 Figure B 38 Opening the Left Side Panel of the Switch 202295 ...

Page 160: ...module fits in the switch recess Step 4 Push the upper module latches down and the lower module latches up to secure the power converter to the switch See Figure B 40 Figure B 40 Pushing the Latches In DC OK 24V 2 1A Rtn Out Pwr Out 125 250V 1 25A MAX 100 240V 50 60Hz N L 202296 DC OK 24V 2 1A Rtn Out Pwr Out 125 250V 1 25A MAX 100 240V 50 60Hz N L Cisco Catalyst Pwr A 24VDC or 48VDC Rtn A Pwr B 2...

Page 161: ...s that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts The interior of the enclosure must be accessible only by the use of a tool The enclosure must meet IP 54 or NEMA type 4 minimum enclosure rating standards Statement 1063 Caution To prevent the switch assemble from overheating there must be a minimum of 3 inches 76 19 mm between a...

Page 162: ... the power converter to an AC power source Preparing the AC Power Cord page B 56 Connecting the AC Power Cord to the Power Converter page B 57 Preparing the AC Power Cord To connect the power converter to an AC power source you need an AC power cord Power cord connector types and standards vary by country Power cord wiring color codes also vary by country You must to have a qualified electrician s...

Page 163: ...d two pole circuit breaker Caution Do not insert the cord into the AC outlet until you finish wiring the line neutral and ground connections To attach the AC power cord to the power supply terminal block follow these steps Step 1 Remove the plastic cover from the input power terminals and set it aside See Figure B 42 Figure B 42 AC DC Power Input Terminal Block Step 2 Insert the exposed ground wir...

Page 164: ...al wire leads into the terminal block line and neutral connections See Figure B 43 Make sure that you cannot see any wire lead Ensure that only wire with insulation extends from the connectors Step 5 Tighten the line and neutral terminal block screws Note The torque should not exceed 2 2 in lb 0 25 Nm Step 6 Replace the plastic cover over the terminal block Step 7 Connect the other end of the AC p...

Page 165: ...Belden part number 9912 or the equivalent Step 2 Measure a length of twisted pair copper wire long enough to connect the power converter to the DC power source For DC connections from the power converter to the DC source use 18 AWG twisted pair copper wire such as Belden part number 9344 or the equivalent Step 3 Using a 18 gauge wire stripping tool strip the ground wire and both ends of the twiste...

Page 166: ... wire labeled number 1 in Figure B 44 lead into the neutral wire connection and the wire labeled number 2 in Figure B 44 lead into the line wire connection Ensure that only wire with insulation extends from the connectors See Figure B 44 Step 8 Tighten the line and neutral terminal block screws Note The torque should not exceed 2 2 in lb 0 25 Nm Step 9 Connect the red wire to the positive pole of ...

Page 167: ...ired to connect the switch to the AC input power supply Attaching the Power Supply to the Switch page B 61 Attaching the Power Supply to the Switch page B 61 Connecting the DC Power Clip page B 62 Connecting the AC Input Power Supply to an AC Power Source page B 63 Attaching the Power Supply to the Switch To attach the AC input power supply to the switch follow these steps Step 1 Remove the left s...

Page 168: ...to live parts The interior of the enclosure must be accessible only by the use of a tool The enclosure must meet IP 54 or NEMA type 4 minimum enclosure rating standards Statement 1063 Caution To prevent the switch assemble from overheating there must be a minimum of 3 inches 76 19 mm between any other device and the top bottom or sides of the switch assembly Connecting the DC Power Clip The DC pow...

Page 169: ...rocedure is intended for a qualified electrician who has selected and prepared an appropriate AC power cord for the PWR IE50W AC power supply Caution AC power sources must be on dedicated AC branch circuits Each branch circuit must be protected by a dedicated two pole circuit breaker Caution Do not insert the power cord plug into the AC outlet until you have completed wiring the line neutral and g...

Page 170: ...fers quick configuration and monitoring You can access the device manager from anywhere in your network through a web browser For more information see the switch getting started guide and the device manager online help Start the Cisco Network Assistant application which is described in the Getting Started with Cisco Network Assistant guide Through this GUI you can configure and monitor a switch cl...

Page 171: ... wires The ports use standard RJ 45 connectors and Ethernet pinouts with internal crossovers Figure C 1 shows the pinouts Connecting to 10BASE T and 100BASE TX Compatible Devices When connecting the ports to 10BASE T and 100BASE TX compatible devices such as servers workstations and routers you can use a two or four twisted pair straight through cable wired for 10BASE T and 100BASE TX Figure C 5 s...

Page 172: ...necting the ports to other devices such as switches or repeaters you must use a four twisted pair Category 5 crossover cable Figure C 8 shows the crossover cable schematics Note Use a straight through cable to connect two ports only when one port is designated with an X Use a crossover cable to connect two ports when both ports are designated with an X or when both ports do not have an X Figure C ...

Page 173: ...r means of security Statement 1072 Each of the four PoE ports on the IEM 3000 4PC or the IEM 3000 4PC 4TC deliver up to 15 4 W of PoE Two ports on each PoE expansion module can also be configured as PoE ports up to 30 W of PoE for non office computer room environments IEC 60950 The remainder of the ports are non PoE On a per port basis you can control whether or not a PoE port automatically provid...

Page 174: ...FP transceivers for fiber optic uplink ports see Figure C 3 and for copper SFP ports see Figure C 4 See the switch release notes for a list of supported SFP transceivers Warning Invisible laser radiation may be emitted from disconnected fibers or connectors Do not stare into beams or view directly with optical instruments Figure C 4 Copper SFP Transceiver RJ 45 Connector 60915 2 3 1 4 5 6 7 8 Pin ...

Page 175: ...male DTE adapter if you want to connect the switch console port to a terminal You can order a kit part number ACS DSBUASYN containing that adapter from Cisco For console port and adapter pinout information see Table C 2 and Table C 3 Cable and Adapter Specifications These sections describe the cables and adapters used with Cisco IE 3000 switches SFP Transceiver Cable Specifications page C 5 Two Tw...

Page 176: ...km 1000BASE ZX GLC ZX SM RGD 1550 SMF G 6522 43 4 to 62 miles 70 to 100 km 2 1000BASE BX D GLC BX40 D I GLC BX40 DA I GLC BX80 D I 1550 1490 1570 SMF G 652 24 9 miles 40 km 24 9 miles 40 km 49 8 miles 80 km 1000BASE BX U GLC BX40 U I GLC BX80 U I 1310 1490 SMF G 652 24 9 miles 40 km 49 8 miles 80 km Commercial SFPs 1000BASE BX10 D GLC BX D 1490 TX 1310 RX SMF G 6523 32 810 feet 10 km 1000BASE BX10...

Page 177: ...F 328 feet 100 m Extended temperature SFPs 1000BASE LX LH SFP GE L 1300 MMF or SMF 62 2 50 50 9 10 500 400 500 1804 feet 550 m 1804 feet 550 m 1804 feet 550 m 6 2 miles 10 km 1000BASE LX LH GLC LH SMD 1310 MMF SMF 62 5 50 0 50 0 G 652 500 400 500 1804 feet 550 m 1804 feet 550 m 1804 feet 550 m 6 2 miles 10 km 100BASE SX SFP GE S 850 MMF 62 5 62 5 50 0 50 0 160 200 400 500 722 feet 220 m 902 feet 2...

Page 178: ...ASE EX GLC EX SMD 1310 SMF G 6522 24 9 miles 40 km 1 Modal bandwidth applies only to multimode fiber 2 1000BASE ZX SFP modules can send data up to 62 miles 100 km by using dispersion shifted SMF or low attenuation SMF the distance depends on the fiber quality the number of splices and the connectors 3 A mode field diameter cladding diameter 9 micrometers 125 micrometers When the fiber optic cable ...

Page 179: ...0 100 1000 ports on the Cisco IE 3000 switches Figure C 7 Four Twisted Pair Straight Through Cable Schematic for 10 100 1000 Ports Figure C 8 Four Twisted Pair Crossover Cable Schematics for 10 100 1000 Ports Switch 3 TD 6 TD 1 RD 2 RD Switch 3 TD 6 TD 1 RD 2 RD H5579 1 TPO 2 TPO 3 TP1 6 TP1 1 TP1 Switch Router or PC 2 TP1 3 TPO 6 TPO 4 TP2 5 TP2 7 TP3 8 TP3 4 TP3 5 TP3 7 TP2 8 TP2 65272 1 TP0 2 T...

Page 180: ...e pin on the outside of the left plug should be a different color from the wire connected to the pin on the inside of the right plug See Figure C 9 Figure C 9 Identifying a Crossover Cable Adapter Pinouts Table C 2 lists the pinouts for the console port the RJ 45 to DB 9 adapter cable and the console device Pin 1 200915 Pin 1 Pin 1 on one connector and pin 1 on the other connector should be differ...

Page 181: ...d the console device Note The RJ 45 to DB 25 female DTE adapter is not supplied with the switch You can order a kit part number ACS DSBUASYN containing this adapter from Cisco Table C 3 Console Port Signaling Using a DB 25 Adapter Switch Console Port DTE RJ 45 to DB 25 Terminal Adapter Console Device Signal DB 25 Pin Signal RTS 5 CTS DTR 6 DSR TxD 3 RxD GND 7 GND GND 7 GND RxD 2 TxD DSR 20 DTR CTS...

Page 182: ...C 12 Cisco IE 3000 Switch Hardware Installation Guide Appendix C Cable and Connectors Cable and Adapter Specifications ...

Page 183: ...necting the console port of the switch to your PC or workstation and accessing the switch through a terminal emulation program To connect to the console port follow these steps 1 Using the supplied RJ 45 to DB 9 adapter cable insert the RJ 45 connector into the console port on the switch front panel Figure 1 1 and to the PC or terminal port 2 Start the terminal emulation program on the PC or termi...

Page 184: ...r network administrator before you complete the setup program Switch IP address Subnet mask IP netmask Default gateway router Enable secret password Enable password Telnet password Completing the Setup Program Follow these steps to complete the setup program and to create an initial configuration for the switch Step 1 Enter Yes at these two prompts Would you like to enter the initial configuration...

Page 185: ...e that connects to the management network and press Return For this release always use vlan1 as that interface Enter interface name used to connect to the management network from the above interface summary vlan1 Step 8 Configure the interface by entering the switch IP address and subnet mask and pressing Return The IP address and subnet masks shown below are examples Configuring interface vlan1 C...

Page 186: ...time the switch reboots save it in NVRAM by selecting option 2 Enter your selection 2 2 Make your selection and press Return After you complete the setup program the switch can run the default configuration that you created If you want to change this configuration or want to perform other management tasks use one of these tools Command line interface CLI Cisco Network Assistant for one or more swi...