23
IR510 WPAN Gateway and IR530 WPAN Range Extender Hardware Installation Guide
IR530 Series Resilient Mesh Range Extender Installation
Figure 12
Grounding Accessory Kit
1.
To ground the range extender, use a crimping tool to crimp the 6-gauge ground wire to the grounding lug.
Figure 13
Figure 13
Crimping the Ground Lug
2.
Connect the grounding lug to the IR530 WPAN Range Extender ground connection point using the supplied screws (
Figure 14
).
Tighten the screws to 10 to 12 foot-pounds of torque.
3.
If necessary, strip the other end of the ground wire and connect it to a reliable earth ground, such as a grounding rod or an appropriate
grounding point on a pole that is grounded.
300622
1
2
391287