1-11
Cisco ME 6500 Series Ethernet Switch Installation Guide
OL-8900-01
Chapter 1 Product Overview
Cisco ME 6524 Ethernet Switch (ME-C6524GT-8S)
Physical Characteristics
Dimensions (H x W x D)
•
2.58 x 17.29 x 19.00 in. (6.54 x 43.92 x 48.26 cm).
•
Chassis requires 1.5 RU
1
.
•
Chassis can be mounted in 19-inch equipment racks that meet
ANSI/EIA 310-D and ETS 300-119 standards.
Weight
29.13 lb (13.21 kg).
Airflow
•
FAN-C6524—110 CFM
Note
To maintain proper air circulation through the switch chassis, we
recommend that you maintain a minimum 6-inch (15 cm) separation
between a wall and the chassis air intake or a wall and the chassis air
exhaust. You should also allow a minimum separation of 12 inches
(30.5 cm) between the hot air exhaust on one chassis and the air
intake on another chassis. Failure to maintain adequate air space can
cause the chassis to overheat and the system to fail.
1.
RU = rack units
Table 1-6
Cisco ME 6524 Ethernet Switch (ME-C6524GT-8S) Front Panel LEDs
LED
Color/Meaning
PS1
(Power supply 1)
Green—Power supply is on and the input and output voltages are OK.
Red—The power supply has a fault.
Off—The power supply is off or is not installed.
PS2
(Power supply 2)
Green—Power supply is on and the input and output voltages are OK.
Red—The power supply has a fault.
Off—The power supply is off or is not installed.
FAN
Green—Fan tray is operating normally.
Red—One or more individual fans in the fan tray have failed.
STATUS
Green—The system is operating normally.
Red—A fault has been detected in the system.
Amber—The system is booting up.
Off—The system is not powered up.
Table 1-5
Cisco ME 6524 Ethernet Switch (ME-C6524GT-8S) Specifications (continued)
Item
Specification