background image

was not used, the GR62 can still be secured using a Kensington lock.

Power the GR62

If mounting to an electrical junction box, feed the Ethernet cable through the cable access hole in the mount cradle. If mounting to a wall or ceiling, the Ethernet
cable will feed from behind the GR62. The "

Power Source Options

" section of this document lists the different powering options and their unique characteristics.

Verify Device Functionality and Test Network Coverage

1. Check LEDs

a. The Power LED should be solid green (or blue, if clients are connected). If it is flashing blue, the firmware is

automatically upgrading and the LED should turn green when the upgrade is completed (normally within a
few minutes). See the "

LED Indicators

" section for more details. .

b. Note: Your GR62 must have an active route to the Internet to check and upgrade its firmware.

2. Verify access point connectivity

a. Use any 802.11 client device to connect to the GR62 and verify proper connectivity using the client’s web

browser.

3. Check network coverage

4. Confirm that you have good signal strength throughout your coverage area. You can use the signal strength meter

on a laptop, smart phone, or other wireless device.

Troubleshooting

Reference the

MR Product Page

for additional information and troubleshooting tips.

Regulatory

This equipment is for indoor use only and the PoE device is considered unlikely to connect to an Ethernet network with outside plant routing, including campus
environments.

FCC Compliance Statement

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.

FCC Interference Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to correct the interference by one of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

15

Summary of Contents for Meraki Go GR62

Page 1: ...62 Installation Guide The Cisco Meraki GR62 is a dual band enterprise class 802 11ax cloud managed access point Package Contents The GR62 package contains the following GR62 Cloud Managed Access Point Mount plate 1 ...

Page 2: ... Mount Kit Wall screws wall screw anchors and security screws Understanding the GR62 Your Meraki GR62 has the following features 2 ...

Page 3: ...3 ...

Page 4: ... information about system functionality and performance Orange AP is booting permanent Orange suggests hardware issue Rainbow AP is initializing scanning Blinking Blue AP is upgrading Green AP in Gateway mode with no clients Blue AP in Gateway mode with clients Blinking Orange AP can t find uplink The GR62 may be operated in Run Dark mode for additional security and to reduce the visibility of the...

Page 5: ...tures of the wireless network such as 802 1X authentication may rely on the property that the APs have static IP addresses Static Assignment Static IPs are assigned using the local web server on each AP The following procedure describes how to set the static IP 1 Using a client machine e g a laptop connect to the AP wirelessly by associating to any SSID broadcast by the AP or over a wired connecti...

Page 6: ...e DHCP reservations Collect Tools You will need the following tools to perform an installation Collect Additional Hardware for Installation You will need the following hardware to perform an installation Installation Instructions 6 ...

Page 7: ... other Meraki devices A Cisco Partner can help ensure that your AP placement is ideal Mount the GR62 Attach the GR62 to the Mount Cradle The GR62 attaches to the mount cradle with two tabs on the cradle that insert into the GR62 and is secured to the cradle using one screw To attach the GR62 to the mount cradle properly line up the top edge of the AP with the top tab of the mount cradle Since the ...

Page 8: ...8 ...

Page 9: ...9 ...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...12 ...

Page 13: ...13 ...

Page 14: ...b Desk or Shelf Mount The GR62 can be placed on a desk or shelf resting on the non scratch rubber feet The mount cradle is not necessary for a desk or shelf installation Secure the GR62 Depending on your mounting environment you may want to secure the GR62 to its mount location Your GR62 can be secured in several ways If the GR62 has been installed using the mount cradle it should be secured via s...

Page 15: ...r indoor use only and the PoE device is considered unlikely to connect to an Ethernet network with outside plant routing including campus environments FCC Compliance Statement This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including inter...

Page 16: ... fonctionnement indésirable Industry Canada Caution i the device for operation in the band 5150 5250 MHz is only for indoor use to reduce the potential for harmful interference to co channel mobile satellite systems ii high power radars are allocated as primary users i e priority users of the bands 5250 5350 MHz and 5650 5850 MHz and that these radars could cause interference and or damage to LE L...

Page 17: ...電磁波曝露量MPE標準值1mW cm2 本產品使用時建議應距離人體 20 cm 1 使用此產品時應避免影響附近雷達系統之操作 2 高增益指向性天線只得應用於固定式點對點系統 17 ...

Reviews: