6-53
Cisco MGX 8850 Routing Switch Command Reference
Release 2.0, Part Number 78-10467-04 Rev C0, October 2001
Chapter 6
Logical Node, Port, and Signaling Commands
cnfsscop
cnfsscop
Configure SSCOP
The cnfsscop command lets you configure service-specific connection-oriented protocol (SSCOP) on a
port. You can use this command regardless of the state of the port. You must specify at least one of the
optional parameters.
Cards on Which This Command Runs
PXM45
Syntax
cnfsscop <portid>
[-polltmr {poll-timer | 0}]
[-keepalivetmr {keepalive-timer | 0}]
[-idletmr {idle-timer | 0}]
[-cctmr {cc-timer | 0}]
[-norsptmr {noresponse-timer | 0}]
[-t309tmr {t309-timer | 0}]
[-maxcc {retries | 0}]
[-sndwnd {send-window-packets | 0}]
[-rcvwnd {recv-window-packets | 0}]
Syntax Description
portid
The portid is the PNNI physical port. The format is
[shelf.]slot[:subslot].port[:subport]. See also
PNNI Format, page 6-4
.
-polltmr
Number of seconds to send POLL PDUs in the active phase. A 0 forces restore of the
default value.
Range: 1–5 seconds
Default: 1 second
-keepalivetmr Number of seconds to send POLL PDUs in the transient phase. 0 forces restore of the
default value.
Range: 1–10 seconds
Default: 5 seconds
-idletmr
Number of seconds to send POLL PDUs in the idle phase. 0 forces restore of the
default value.
Range: 1–20 seconds
Default: 10 seconds
-cctmr
Number of seconds to send BGN/END/RS/ER PDUs at the connection control phase.
0 forces restore of the default value.
Range: 1–5 seconds
Default: 1 second