event fanabsent
event fanabsent
To specify an event criteria for an Embedded Event Manager (EEM) applet that is run on the basis of a
fan absent event, use the
event fanabsent
command. To remove the fan absent event criteria, use the
no
form of this command.
event fanabsent
[
fan
number
]
time
interval
no event fanabsent
[
fan
number
]
time
interval
Syntax Description
Defaults
None
Command Modes
Embedded event manager configuration mode
Command History
Usage Guidelines
This command does not require a license.
Examples
This example shows how to specify that an EEM applet runs when a fan absent event occurs:
switch#
configure terminal
switch(config)#
event manager applet absent-applet
switch(config-applet)#
event fanabsent time 600
switch(config-applet)#
fan
number
(Optional) Specifies a fan number to monitor for a fan absent event. The range is
from 1 to 1.
time
interval
Specifies the time interval in seconds within which the fan can stay absent. The
range is from 10 to 64000.
Release
Modification
5.0(3)U3(1)