S e n d c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m
-SM-182
Cisco Nexus 3000 Series NX-OS System Management Command Reference
OL-29557-04
Chapter System Management Commands
sflow counter-poll-interval
sflow counter-poll-interval
To configure an interval between sample counters associated with the datagram, use the
sflow
collector-poll-interval
command. To remove the interval, use the
no
form of this command.
sflow counter-poll-interval
poll-interval
no sflow counter-poll-interval
poll-interval
Syntax Description
Defaults
None
Command Modes
Global configuration
Command History
Usage Guidelines
A sampling interval of 0 disables counter sampling.
This command does not require a license.
Examples
This example shows how to configure the sFlow poll interval for an interface.
switch#
configure terminal
switch(config)#
sflow counter-poll-interval 100
switch(config)#
copy running-config startup-config
Related Commands
poll-interval
Poll interval for an interface. The range for the
poll-interval
is from 0 to
2147483647 seconds. The default value is 20.
Release
Modification
5.0(3)U4(1)
This command was introduced.
Command
Description
feature sflow
Enables sFlow.
show sflow
Displays sFlow information.