8-22
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
OL-23069-06
Appendix 8 Managing the Switch Hardware
Shutting Down Modules
DETAILED STEPS
Note
To exit the console mode, enter the
~,
command.
Shutting Down Modules
This section includes the following topics:
•
Shutting Down a Supervisor, page 8-22
•
Shutting Down a Fabric Module, page 8-22
•
Shutting Down an I/O Module, page 8-23
Shutting Down a Supervisor
To shut down a supervisor module, use the
out-of-service module
command to specify the slot with that
module as follows:
switch#
out-of-service module
slot
Shutting Down a Fabric Module
To shut down a fabric module, use either the
out-of-service xbar
command or the
poweroff xbar
command. If you use the
poweroff
command, the slot remains in that state until you use the
no poweroff
command. If you use the
out-of-service
command, the
out-of-service
state remains in effect until you
do something like remove the module and replace it with another module.
Note
If you are going to limit the maximum number of fabric modules (see the
“Changing the Amount of
Power Reserved for Fabric Modules” section on page 8-30
), make sure that powered-on fabric modules
are in the first
n
fabric module slots, where
n
is the new maximum number of fabric modules. For
example, if you are limiting the maximum number of fabric modules to 4, you must make sure that the
four powered-on fabric modules are in fabric slots 1 through 4.
Command
Purpose
Step 1
attach console module
slot_number
Example:
switch# attach console module 9
Connected
Escape character is ‘~,’ (tilde
comma]
Attaches the console port for the I/O module slot number
specified.
Summary of Contents for Nexus 7004
Page 12: ...Contents xii Cisco Nexus 7000 Series Hardware Installation and Reference Guide OL 23069 07 ...
Page 19: ... xix Cisco Nexus 7000 Series Hardware Installation and Reference Guide OL 23069 07 ...
Page 22: ... xxii Cisco Nexus 7000 Series Hardware Installation and Reference Guide OL 23069 07 ...