10-24
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
OL-23069-07
Chapter 10 Installing or Replacing Components
Replacing a Supervisor Module
To migrate from using Supervisor 1 modules to Supervisor 2 or Supervisor 2E modules, follow these
steps:
Step 1
Insert a USB drive in the top USB port (usb1) in the active supervisor 1 module. If the Supervisor 2 or
Supervisor 2E module shipped with an extra USB drive, you can insert that USB drive in the usb1 drive
on the Supervisor 1 module.
Note
Do not use the USB drive that is in the LOG FLASH port.
Step 2
Format the drive by using the
format
command.
switch(config)#
format usb1:
Step 3
Copy all of the VDC configurations for the switch to the USB drive by using the
copy running-config
command.
switch(config)#
copy running-config usb1:
configuration_file_name
vdc-all
Step 4
Backup the installed licenses for the switch to the USB drive by using the
copy licenses
command.
switch(config)#
copy licenses usb1:
licenses_archive_file_name
.tar
Note
You must use the
tar
extension for the archive file. This file will contain all of the license files that were
installed on the Supervisor 1 module.
Step 5
Determine the Cisco NX-OS software release to use on the Supervisor 2 or Supervisor 2E modules. We
support Cisco NX-OS Release 6.1(1) (or later release) on those modules but another one might be
recommended. Additionally, the most recommended maintenance release might not be the one that ships
with the Supervisor 2 or Supervisor 2E modules. We recommend that you check with the following
documents for the recommended software release:
•
Minimum Recommended Cisco NX-OS Releases for Cisco Nexus 7000 Series Switches
•
Cisco Nexus 7000 Series NX-OS Release Notes, Release 6.1
Step 6
Copy the Supervisor 2 or Supervisor 2E version of the kickstart, system, and EPLD (optional) images to
the USB drive by using the
copy
command.
switch(config)# copy scp://
path
/n7000-s2-kickstart.6.1.1.bin usb1:
switch(config)# copy scp://
path
/n7000-s2-dk9.6.1.1.bin usb1:
switch(config)# copy scp://
path
/n7000-s2-epld.6.1.1.img usb1:
Note
This example specifies the NX-OS Release 6.1(1) images. For a later release, use the later release
number in the .bin or .img file name.
Caution
Use -s2- images with Supervisor 2 or Supervisor 2E modules. If you use an -s1- image with a Supervisor
2 or Supervisor 2E module, the supervisor will not boot up.
Summary of Contents for Nexus 7004
Page 12: ...Contents xii Cisco Nexus 7000 Series Hardware Installation and Reference Guide OL 23069 07 ...
Page 19: ... xix Cisco Nexus 7000 Series Hardware Installation and Reference Guide OL 23069 07 ...
Page 22: ... xxii Cisco Nexus 7000 Series Hardware Installation and Reference Guide OL 23069 07 ...