D-3
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
OL-23069-07
Appendix D Chassis and Module LEDs
Supervisor Module LEDs
MGMT ETH
Green
The management port is operational.
Amber
The management port link has been disabled through the software.
Flashing
Amber
The management port link is bad and has been disabled due to a hardware
failure.
Off
The module has not detected a signal.
LINK
Green
The module has detected a link.
Off
The module does not detect a link.
ACT
Flashing green
The module is transmitting or receiving.
Off
The module is not transmitting or receiving.
ACT LOG FLASH
(Supervisor 1)
LOG FLASH
(Supervisor 2 and 2E)
Green
The log flash CompactFlash or USB disk is being accessed. Do not remove
the media until the LED is off.
Off
The expansion flash CompactFlash or USB disk is not being accessed. You
can remove the media while this LED is off.
ACT EXPANSION FLASH
(Supervisor 1)
Slot 0
(Supervisor 2 and 2E)
Green
The expansion flash CompactFlash or USB disk is being accessed. Do not
remove the media until the LED is off.
Off
The log flash CompactFlash or USB disk is not being accessed. You can
remove the media while this LED is off.
CMP MGMT ETH
(Supervisor 1 module only)
Green
The management port is operational.
Amber
The management port link has been disabled through the software.
Flashing amber The management port link is bad and has been disabled due to a hardware
failure.
Off
The module does not detect a signal.
CMP STATUS
(Supervisor 1 module only)
Green
All diagnostics pass. The CMP is operational (normal initialization
sequence).
Amber
Sufficient power is not available for all modules.
Flashing amber The diagnostic test has failed.
or
The CMP is not operational because a fault has occurred during the
initialization sequence.
Red
The module has detected a slot ID parity error.
Off
The CMP is not receiving power.
LINK
(Supervisor 1 module only)
Green
The module has detected a link.
Off
The module has not detected a link.
ACT
(Supervisor 1 module only)
Flashing green
The module is transmitting or receiving.
Off
The module is not transmitting or receiving.
Table D-2
Supervisor Module LEDs (continued)
LED
Status
Description
Summary of Contents for Nexus 7004
Page 12: ...Contents xii Cisco Nexus 7000 Series Hardware Installation and Reference Guide OL 23069 07 ...
Page 19: ... xix Cisco Nexus 7000 Series Hardware Installation and Reference Guide OL 23069 07 ...
Page 22: ... xxii Cisco Nexus 7000 Series Hardware Installation and Reference Guide OL 23069 07 ...