S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - d o c f e e d b a c k @ c i s c o . c o m
E-4
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
OL-23069-06
Appendix E Repacking the Cisco Nexus 7000 Series Switch for Shipment
Repacking the System Components
e.
Disconnect the grounding lug from the lower front side of the power supply unit by unscrewing its
two M6 nuts and pulling the grounding lug off of the power supply unit. For the location of the
grounding pad, see
Warning
When installing or replacing the unit, the ground connection must always be made first and
disconnected last.
Statement 1046
Step 4
Remove each power supply unit and repack it as follows:
Note
These instructions are for the multi-unit power supply box that comes with newer Cisco Nexus
7010 switches. If you have the single-unit box for the 6-kW AC power supply unit, see
for packing instructions. If you have the single-unit box for the 6-kW
DC power supply unit, see
for packing instructions.
a.
Open the box for the power supply units and make sure that the cardboard holders are set up inside
the box (see Callout 1 in
).