Cisco Nexus 7000 Series Hardware Installation and Reference Guide
OL-23069-06
Chapter 7 Managing the Switch Hardware
Displaying Power Usage Information
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
00 00
License software-module specific block:
Block Signature : 0x6006
Block Version : 1
Block Length : 16
Block Checksum : 0x77
lic usage bits:
00 00 00 00 00 00 00 00
Second Serial number specific block:
Block Signature : 0x6007
Block Version : 1
Block Length : 28
Block Checksum : 0x312
Serial Number : TBM11476798
switch#
Displaying Power Usage Information
To display the actual power usage information for the entire switch, use the
show environment power
command. See
. This command shows the power usage for many of the modules in the
switch. For the older modules that do not have the capability to output this information, the output is
shown as N/A.
Note
In a Cisco Nexus 7000 Series switch, power usage is reserved for both supervisor modules regardless of
whether one or both supervisor modules are present.
Example 7-4
Displaying Power Management Information
switch#
show environment power
Power Supply:
Power Supply:
Voltage: 50 Volts
Power Actual Total
Supply Model Output Capacity Status
(Watts ) (Watts )
------- ------------------- ----------- ----------- --------------
1 N7K-AC-6.0KW 812 W 6000 W Ok
2 N7K-AC-6.0KW 704 W 6000 W Ok
3 N7K-AC-6.0KW 727 W 6000 W Ok
Actual Power
Module Model Draw Allocated Status
(Watts ) (Watts )
------- ------------------- ----------- ----------- --------------
2 N7K-M148GT-11 N/A 400 W Powered-Up
3 N7K-M148GT-11 N/A 400 W Powered-Up
4 N7K-M148GT-11 N/A 400 W Powered-Up
5 N7K-SUP1 N/A 210 W Powered-Up
6 N7K-SUP1 N/A 210 W Powered-Up
7 N7K-M132XP-12 N/A 750 W Powered-Up
9 N7K-M148GS-11 284 W 400 W Powered-Up
Xb1 N7K-C7010-FAB-1 N/A 60 W Powered-Up
Xb2 N7K-C7010-FAB-1 N/A 60 W Powered-Up